diff options
| author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 | 
|---|---|---|
| committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2019-07-31 17:00:20 +0200 | 
| commit | 3759ce55ba79b8d3b9d8ed247a252273ee7dade3 (patch) | |
| tree | d69692a274dd1c7d0672e6bb7155a0fc106f9d49 /backend/plustek-usbcal.c | |
| parent | c8bd2513ecba169cff44c09c8058c36987357b18 (diff) | |
| parent | 1687222e1b9e74c89cafbb5910e72d8ec7bfd40f (diff) | |
Update upstream source from tag 'upstream/1.0.28'
Update to upstream version '1.0.28'
with Debian dir ec5bb298266630fc3801ff6dc0c258f6df7ba979
Diffstat (limited to 'backend/plustek-usbcal.c')
| -rw-r--r-- | backend/plustek-usbcal.c | 38 | 
1 files changed, 19 insertions, 19 deletions
| diff --git a/backend/plustek-usbcal.c b/backend/plustek-usbcal.c index f2e7608..3b9d93a 100644 --- a/backend/plustek-usbcal.c +++ b/backend/plustek-usbcal.c @@ -21,7 +21,7 @@   * or can test.   *   * Therefore, I'm splitting out a few calibration functions I need - * to modify for the CanoScan which allows me to simplify things  + * to modify for the CanoScan which allows me to simplify things   * greatly for the CanoScan without worrying about breaking other   * scanners, as well as reuse the vast majority of the Plustek   * driver infrastructure without forking. @@ -109,7 +109,7 @@ cano_PrepareToReadWhiteCal( Plustek_Device *dev, SANE_Bool mv2shading_pos )  {  	SANE_Bool goto_shading_pos = SANE_TRUE;  	HWDef     *hw = &dev->usbDev.HwSetting; -	 +  	switch (strip_state) {  		case 0:  			if( !usb_IsSheetFedDevice(dev)) { @@ -152,7 +152,7 @@ cano_PrepareToReadBlackCal( Plustek_Device *dev )  	if( strip_state == 0 )  		if(cano_PrepareToReadWhiteCal(dev, SANE_FALSE))  			return SANE_FALSE; -			 +  	if( strip_state != 2 ) {  	    /*  		 * if we have a dark shading strip, there's no need to switch @@ -203,7 +203,7 @@ cano_LampOnAfterCalibration( Plustek_Device *dev )   * @param max - pointer to the max OFF point for the CIS-channel   * @param off - pointer to the current OFF point of the CIS-channel   * @param val - current value to check - * @return returns 0 if the value is fine, 1, if we need to adjust  + * @return returns 0 if the value is fine, 1, if we need to adjust   */  static int  cano_adjLampSetting( u_short *min, u_short *max, u_short *off, u_short val ) @@ -249,7 +249,7 @@ cano_adjLampSetting( u_short *min, u_short *max, u_short *off, u_short val )   * coarse calibration step 0   * [Monty changes]: On the CanoScan at least, the default lamp   * settings are several *hundred* percent too high and vary from - * scanner-to-scanner by 20-50%. This is only for CIS devices  + * scanner-to-scanner by 20-50%. This is only for CIS devices   * where the lamp_off parameter is adjustable; I'd make it more general,   * but I only have the CIS hardware to test.   */ @@ -305,7 +305,7 @@ cano_AdjustLightsource( Plustek_Device *dev )  	min_rgb.Green = hw->green_lamp_on;  	min_rgb.Blue  = hw->blue_lamp_on; -	if((dev->adj.rlampoff != -1) &&  +	if((dev->adj.rlampoff != -1) &&  	   (dev->adj.glampoff != -1) && (dev->adj.rlampoff != -1)) {  		DBG( _DBG_INFO, "- function skipped, using frontend values!\n" );  		return SANE_TRUE; @@ -393,10 +393,10 @@ cano_AdjustLightsource( Plustek_Device *dev )  			DBG( _DBG_INFO2, "red_lamp_off  = %u/%u/%u\n",  			                  min_rgb.Red ,hw->red_lamp_off, max_rgb.Red );  		} -			 +  		DBG( _DBG_INFO2, "green_lamp_off = %u/%u/%u\n",  		                  min_rgb.Green, hw->green_lamp_off, max_rgb.Green ); -							 +  		if( m_ScanParam.bDataType == SCANDATATYPE_Color ) {  			DBG( _DBG_INFO2, "blue_lamp_off = %u/%u/%u\n",  			                  min_rgb.Blue, hw->blue_lamp_off, max_rgb.Blue ); @@ -528,7 +528,7 @@ cano_AdjustGain( Plustek_Device *dev )  	DBG( _DBG_INFO, "cano_AdjustGain()\n" );  	if( !usb_InCalibrationMode(dev)) { -		if((dev->adj.rgain != -1) &&  +		if((dev->adj.rgain != -1) &&  		   (dev->adj.ggain != -1) && (dev->adj.bgain != -1)) {  			setAdjGain( dev->adj.rgain, &dev->usbDev.a_bRegs[0x3b] );  			setAdjGain( dev->adj.ggain, &dev->usbDev.a_bRegs[0x3c] ); @@ -559,11 +559,11 @@ cano_AdjustGain( Plustek_Device *dev )  	DBG( _DBG_INFO2, "Pixels   = %lu\n", m_ScanParam.Size.dwPixels );  	DBG( _DBG_INFO2, "Bytes    = %lu\n", m_ScanParam.Size.dwBytes  );  	DBG( _DBG_INFO2, "Origin.X = %u\n",  m_ScanParam.Origin.x ); -   +  	while( adj ) {  		m_ScanParam.dMCLK = dMCLK; -  +  		if( !usb_SetScanParameters( dev, &m_ScanParam ))  			return SANE_FALSE; @@ -615,7 +615,7 @@ cano_AdjustGain( Plustek_Device *dev )  				dwR = dwR / dwDiv;  				dwG = dwG / dwDiv;  				dwB = dwB / dwDiv; -	 +  				if(max_rgb.Red < dwR)  					max_rgb.Red = dwR;  				if(max_rgb.Green < dwG) @@ -764,7 +764,7 @@ cano_AdjustOffset( Plustek_Device *dev )  	u_long   *scanbuf = dev->scanning.pScanBuffer;  	HWDef    *hw      = &dev->usbDev.HwSetting;  	DCapsDef *scaps   = &dev->usbDev.Caps; -	 +  	if( usb_IsEscPressed())  		return SANE_FALSE; @@ -977,13 +977,13 @@ cano_AdjustDarkShading( Plustek_Device *dev, u_short cal_dpi )  	/* average the n lines, compute reg values */  	if( scan->sParam.bDataType == SCANDATATYPE_Color ) { -		 +  		stepW = m_ScanParam.Size.dwPhyPixels;  		if( usb_IsCISDevice(dev))  			step = m_ScanParam.Size.dwPhyPixels + 1;  		else  			step = (m_ScanParam.Size.dwPhyPixels*3) + 1; -		 +  		for( i=0; i<m_ScanParam.Size.dwPhyPixels; i++ ) {  			red   = 0; @@ -1036,7 +1036,7 @@ cano_AdjustDarkShading( Plustek_Device *dev, u_short cal_dpi )  		step = m_ScanParam.Size.dwPhyPixels + 1;  		for( i=0; i<m_ScanParam.Size.dwPhyPixels; i++ ) { -			 +  			gray = 0;  			bufp = ((u_short *)scanbuf)+i; @@ -1252,7 +1252,7 @@ cano_DoCalibration( Plustek_Device *dev )  		DBG( _DBG_INFO2, "###### ADJUST OFFSET (COARSE) ####\n" );  		if(cano_PrepareToReadBlackCal(dev))  			return SANE_FALSE; -		 +  		if( !cano_AdjustOffset(dev)) {  			DBG( _DBG_ERROR, "Coarse Calibration failed!!!\n" );  			return SANE_FALSE; @@ -1261,7 +1261,7 @@ cano_DoCalibration( Plustek_Device *dev )  		DBG( _DBG_INFO2, "###### ADJUST GAIN (COARSE)#######\n" );  		if(cano_PrepareToReadWhiteCal(dev, SANE_FALSE))  			return SANE_FALSE; -		 +  		if( !cano_AdjustGain(dev)) {  			DBG( _DBG_ERROR, "Coarse Calibration failed!!!\n" );  			return SANE_FALSE; @@ -1367,7 +1367,7 @@ cano_DoCalibration( Plustek_Device *dev )  	if( !usb_IsSheetFedDevice(dev))  		usb_ModuleToHome( dev, SANE_TRUE );  	scan->fCalibrated = SANE_TRUE; -	 +  	DBG( _DBG_INFO, "cano_DoCalibration() done\n" );  	DBG( _DBG_INFO, "-------------------------\n" );  	DBG( _DBG_INFO, "Static Gain:\n" ); | 
