summaryrefslogtreecommitdiff
path: root/doc/sane-epson.man
diff options
context:
space:
mode:
authorJörg Frings-Fürst <debian@jff-webhosting.net>2014-10-06 14:00:40 +0200
committerJörg Frings-Fürst <debian@jff-webhosting.net>2014-10-06 14:00:40 +0200
commit6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch)
tree2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/sane-epson.man
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/sane-epson.man')
-rw-r--r--doc/sane-epson.man306
1 files changed, 306 insertions, 0 deletions
diff --git a/doc/sane-epson.man b/doc/sane-epson.man
new file mode 100644
index 0000000..3790df6
--- /dev/null
+++ b/doc/sane-epson.man
@@ -0,0 +1,306 @@
+.TH sane\-epson 5 "11 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
+.IX sane\-epson
+.SH NAME
+sane\-epson \- SANE backend for EPSON scanners
+.SH DESCRIPTION
+The
+.B sane\-epson
+library implements a SANE (Scanner Access Now Easy) backend that
+provides access to Epson flatbed scanners. Some functions of this
+backend should be considered
+.B beta-quality
+software! Most functions have been stable for a long time, but of
+course new development can not and often times will not function properly from
+the very first day. Please report any strange behavior to the
+maintainer of the backend.
+.PP
+At present, the following scanners are known to work with this backend:
+.PP
+.RS
+.ft CR
+.nf
+Model: Connection Type
+--------------------------- -------------------
+GT-5000 SCSI, parallel
+GT-6000 parallel
+GT-6500 SCSI (use only the line "scsi" in epson.conf)
+ActionScanner II SCSI, parallel
+GT-7000 SCSI
+Perfection 636 SCSI
+Perfection 636U USB
+Perfection 610 USB
+Perfection 640 USB
+Perfection 1200S SCSI
+Perfection 1200U USB
+Perfection 1240 USB, SCSI
+Perfection 1640 USB, SCSI
+Perfection 1650 USB
+Perfection 1660 USB
+Perfection 2400 USB
+Perfection 2450 USB, IEEE-1394
+Expression 636 / GT-9500 SCSI
+Expression 1600 USB, SCSI, IEEE-1394
+Expression 1680 USB, SCSI, IEEE-1394
+CX-3200 USB
+CX-5200 USB
+.fi
+.ft R
+and many more. The official list is on the Sane web site.
+.RE
+
+For other scanners the software may or may not work. Please send mail to
+the backend author (khk@khk.net) to report success with scanners not on
+the list or problems with scanners that are listed.
+.SH OPTIONS
+The options the backend supports can either be selected through command line
+options to programs like scanimage or through GUI elements in programs like
+xscanimage or xsane.
+
+Valid command line options and their syntax can be listed by using
+.RS
+scanimage \-\-help \-d epson
+.RE
+Not all devices support all options.
+.TP
+.I Scan Mode
+The
+.I \-\-mode
+switch selects the basic mode of operation of the scanner. Valid choices
+are Binary, Gray and Color. The Binary mode is black and white only,
+Gray will produce 256 levels of gray or more depending on the scanner
+and Color means 24 bit color mode or more depending on the scanner.
+Some scanners will internally use 36 bit color, their external interface
+however may only support 24 bits.
+
+The
+.I \-\-depth
+option selects the bit depth the scanner is using. This option is only
+available for scanners that support more than one bit depth. Older
+scanners will always transfer the image in 8bit mode. Newer scanners
+allow to select either 8 bits, 12 or 14 bits per color channel. For a
+color scan this means an effective color depth of 36 or 42 bits over
+all three channels. The valid choices depend on the scanner model.
+
+The
+.I \-\-halftoning
+switch selects the mode that is used in Binary mode. Valid options
+are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
+(Net Screen)", "Dither A (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C
+(4x4 Net Screen)", "Dither D (8x4 Net Screen)", "Text Enhanced Technology",
+"Download pattern A", and "Download pattern B".
+
+The
+.I \-\-dropout
+switch selects the so called dropout color. Vald options are None,
+Red, Green and Blue. The default is None. The dropout color is used for
+monochrome scanning and selects the color that is not scanned. This can
+be used to e.g. scan an original with a colored background.
+
+The
+.I \-\-brightness
+switch controls the brightness of the scan. Valid options are integer
+values from \-3 to 3. The default is 0. The larger the brightness value,
+the brighter the image gets. If a user defined table for the gamma
+correction is selected, the brightness parameter is not available.
+
+The
+.I \-\-sharpness
+switch sets the sharpness of the image data. Valid options are integer
+values from \-2 to 2, with \-2 meaning "Defocus", \-1 "Defocus slightly",
+0 "Normal", 1 "Sharpen slightly" and 2 "Sharpen".
+
+The
+.I \-\-gamma\-correction
+switch controls the scanner's internal gamma correction. Valid options are
+"Default", "User defined", "High density printing" "Low density printing"
+and "High contrast printing".
+
+The
+.I \-\-color\-correction
+switch controls the scanner's internal color correction function. Valid
+options are "No Correction", "Impact\-dot printers", "Thermal printers",
+"Ink\-jet printers" and "CRT monitors". The default is "CRT monitors".
+
+The
+.I \-\-resolution
+switch selects the resolution for a scan. Some EPSON scanners will scan in
+any resolution between the lowest and highest possible value. The list
+reported by the scanner can be displayed using the "\-\-help \-d epson"
+parameters to scanimage.
+
+The
+.I \-\-mirror
+option controls the way the image is scanned. By reading the image data
+from right to left the image is mirrored. Valid options are "yes" and
+"no". The default is "no".
+
+The
+.I \-\-speed
+option can improve the scan speed in monochrome mode. Valid options are
+"yes" or "no", the "yes" option will speed up the scan if this option
+is supported.
+
+The
+.I \-\-auto\-area\-segmentation
+switch activates the automatic area segmentation for monochrome scans. The
+scanner will try to determine which areas are text and which contain
+images. The image areas will be halftoned, and the text will be
+improved. Valid options are "yes" and "no". The default is "yes".
+
+The
+.I \-\-gamma\-table
+parameter can be used to download a user defined gamma table. The option
+takes 256 values from the range 0-255. In color mode this option equally
+affects the red, green, and blue channel.
+
+The
+.I \-\-red\-gamma\-table
+parameter can be used to download a user defined gamma table for the
+red channel. The valid options are the same as for \-\-gamma\-table.
+
+The
+.I \-\-green\-gamma\-table
+parameter can be used to download a user defined gamma table for the
+green channel. The valid options are the same as for \-\-gamma\-table.
+
+The
+.I \-\-blue\-gamma\-table
+parameter can be used to download a user defined gamma table for the
+blue channel. The valid options are the same as for \-\-gamma\-table.
+
+The color correction coefficients
+.I \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9
+will install color correction coefficients for the user defined color
+correction. Values are specified as integers in the range \-127..127.
+
+The
+.I \-\-preview
+option requests a preview scan. The frontend software automatically selects a low
+resolution. Valid options are "yes" and "no". The default is "no".
+
+The
+.I \-\-preview\-speed
+options will increase the scan speed if this is supported by the
+scanner. Valid options are "yes" and "no", the default is "no".
+
+
+The geometry options
+.I \-l \-t \-x \-y
+control the scan area: \-l sets the top left x coordinate, \-t the top
+left y coordinate, \-x selects the width and \-y the height of the scan
+area. All parameters are specified in millimeters.
+
+The
+.I \-\-quick\-format
+option lets the user select a scan area with predefined sizes. Valid
+parameters are "CD", "A5 portrait", "A5 landscape", "Letter", "A4" and
+"max". The default is "max", which selects the largest possible area.
+
+The
+.I \-\-source
+option selects the scan source. Valid options depend on the installed
+options. The default is "Flatbed".
+
+The
+.I \-\-auto\-eject
+option will eject a page after scanning from the document feeder.
+
+The
+.I \-\-film\-type
+option will select the film type for scans with the transparency
+unit. This option is only activated if the TPU is selected as scan
+source. Valid options are "Negative Film" and "Positive Film".
+
+The
+.I \-\-focus\-position
+option selects the focus position for all scans. Valid options are "Focus
+2.5mm above glass" and "Focus on glass". The focus on the 2.5mm point
+above the glass is necessary for scans with the transparency unit, so
+that the scanner can focus on the film if one of the film holders is used.
+This option is only functional for selected scanners, all other scanners
+will ignore this option.
+
+
+.SH CONFIGURATION FILE
+The configuration file @CONFIGDIR@/epson.conf specifies the device(s) that the
+backend will use. Possible connection types are:
+.TP
+.I SCSI
+This is the default, and if nothing else is specified the backend software will
+open a given path as SCSI device. More information about valid syntax for SCSI
+devices can be found in sane\-scsi(5).
+.br
+Usually SCSI scanners are configured with a line "scsi EPSON" in this file. In
+some cases it may be necessary to only use the string "scsi" (e.g. for the GT-6500).
+.TP
+.I PIO \- Parallel Interface
+The parallel interface can be configured in two ways: An integer value starting
+at the beginning of a line will be interpreted as the IO address of the parallel
+port. To make it clearer that a configured IO address is a parallel port the
+port address can be preceded by the string "PIO". The PIO connection does not
+use a special device file in the /dev directory. The IO address can be specified
+in hex mode (prefixed with "0x").
+.TP
+.I USB
+A device file that is preceded by the string "USB" is treated as a scanner
+connected via the Universal Serial Bus. The correct special device file has
+to be created prior to using it with Sane. See the USB documentation for
+more information about how to set up the USB subsystem and the required
+device files.
+.SH FILES
+.TP
+.I @LIBDIR@/libsane\-epson.a
+The static library implementing this backend.
+.TP
+.I @LIBDIR@/libsane\-epson.so
+The shared library implementing this backend (present on systems that
+support dynamic loading).
+.SH ENVIRONMENT
+.TP
+.B SANE_DEBUG_EPSON
+If the library was compiled with debug support enabled, this
+environment variable controls the debug level for this backend. E.g.,
+a value of 128 requests all debug output to be printed. Smaller
+levels reduce verbosity.
+.TP
+.B SANE_DEBUG_EPSON_SCSI
+If the library was compiled with debug support enabled, this
+environment variable controls the SCSI related debug level for this backend.
+Only a value of 2 is supported.
+.TP
+.B SANE_EPSON_CMD_LVL
+This allows to override the function or command level that the backend
+uses to communicate with the scanner. The function level a scanner
+supports is determined during the initialization of the device. If
+the backend does not recognize the function level reported by the
+scanner it will default to function level B3. Valid function levels
+are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8, D1 and F5. Use this feature
+only if you know what you are doing!
+
+.SH "SEE ALSO"
+
+sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1)
+
+.SH BUGS
+
+None :-) At least none are currently known.
+
+.SH UNSUPPORTED DEVICES
+The backend may be used with Epson scanners that are not yet listed
+under the list of supported devices. A scanner that is not recognized
+may default to the function level B3, which means that not all
+functions that the scanner may be capable of are accessible.
+
+If the scanner is not even recognized as an Epson scanner this is
+probably because the device name reported by the scanner is not in the
+correct format. Please send this information to the backend maintainer
+(email address is in the AUTHOR section of this man page or in the
+AUTHORS file of the SANE distribution).
+
+The Perfection 600, Perfection 650, Perfection 660, Perfection 1250 and
+Perfection 1260 are not supported by this backend.
+
+.SH AUTHOR
+
+The package is actively maintained by Karl Heinz Kremer (khk@khk.net). The
+software is based on work by Christian Bucher and Kazuhiro Sasayama