diff options
| author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:19 +0100 | 
|---|---|---|
| committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-02-16 18:24:19 +0100 | 
| commit | 351b7328520c16730ceb46e5acae16038c42185e (patch) | |
| tree | fae21fd5c94f3c3ed0202a95c9ada705482e647b /doc/sane-epson.man | |
| parent | ad38bc6ecb80ddeb562841b33258dd53659b1da6 (diff) | |
New upstream version 1.0.32upstream/1.0.32
Diffstat (limited to 'doc/sane-epson.man')
| -rw-r--r-- | doc/sane-epson.man | 105 | 
1 files changed, 63 insertions, 42 deletions
diff --git a/doc/sane-epson.man b/doc/sane-epson.man index f09f075..75ffad3 100644 --- a/doc/sane-epson.man +++ b/doc/sane-epson.man @@ -5,7 +5,7 @@ sane\-epson \- SANE backend for EPSON scanners  .SH DESCRIPTION  The  .B sane\-epson -library implements a SANE (Scanner Access Now Easy) backend that +library implements a SANE Scanner Access Now Easy) backend that  provides access to Epson flatbed scanners.  Some functions of this  backend should be considered  .B beta-quality @@ -49,22 +49,30 @@ and many more. The official list is on the Sane web site.  .RE  For other scanners the software  may or may not work.  Please send mail to -the backend author (khk@khk.net) to report success with scanners not on -the list or problems with scanners that are listed. +the backend author +.RI ( khk@khk.net ) +to report success with scanners not on the list or problems with scanners +that are listed.  .SH OPTIONS  The options the backend supports can either be selected through command line -options to programs like scanimage or through GUI elements in programs like -xscanimage or xsane. - -Valid command line options and their syntax can be listed by using +options to programs like +.BR scanimage (1) +or through GUI elements in programs like +.BR xscanimage (1) +or +.BR xsane (1). + +Valid command line options and their syntax can be listed by using: +.PP  .RS  scanimage \-\-help \-d epson  .RE +.PP  Not all devices support all options.  .TP  .I Scan Mode  The -.I \-\-mode +.B \-\-mode  switch selects the basic mode of operation of the scanner. Valid choices  are Binary, Gray and Color.  The Binary mode is black and white only,  Gray will produce 256 levels of gray or more depending on the scanner @@ -73,7 +81,7 @@ Some scanners will internally use 36 bit color, their external interface  however may only support 24 bits.  The -.I \-\-depth +.B \-\-depth  option selects the bit depth the scanner is using. This option is only  available for scanners that support more than one bit depth. Older  scanners will always transfer the image in 8bit mode. Newer scanners @@ -82,7 +90,7 @@ color scan this means an effective color depth of 36 or 42 bits over  all three channels. The valid choices depend on the scanner model.  The -.I \-\-halftoning +.B \-\-halftoning  switch selects the mode that is used in Binary mode. Valid options  are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C  (Net Screen)", "Dither A (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C @@ -90,129 +98,136 @@ are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C  "Download pattern A", and "Download pattern B".  The -.I \-\-dropout +.B \-\-dropout  switch selects the so called dropout color. Valid options are None,  Red, Green and Blue. The default is None. The dropout color is used for  monochrome scanning and selects the color that is not scanned. This can  be used to e.g. scan an original with a colored background.  The -.I \-\-brightness +.B \-\-brightness  switch controls the brightness of the scan. Valid options are integer  values from \-3 to 3. The default is 0. The larger the brightness value,  the brighter the image gets. If a user defined table for the gamma  correction is selected, the brightness parameter is not available.  The -.I \-\-sharpness +.B \-\-sharpness  switch sets the sharpness of the image data. Valid options are integer  values from \-2 to 2, with \-2 meaning "Defocus", \-1 "Defocus slightly",  0 "Normal", 1 "Sharpen slightly" and 2 "Sharpen".  The -.I \-\-gamma\-correction +.B \-\-gamma\-correction  switch controls the scanner's internal gamma correction. Valid options are  "Default", "User defined", "High density printing" "Low density printing"  and "High contrast printing".  The -.I \-\-color\-correction +.B \-\-color\-correction  switch controls the scanner's internal color correction function. Valid  options are "No Correction", "Impact\-dot printers", "Thermal printers",  "Ink\-jet printers" and "CRT monitors". The default is "CRT monitors".  The -.I \-\-resolution +.B \-\-resolution  switch selects the resolution for a scan. Some EPSON scanners will scan in  any resolution between the lowest and highest possible value. The list  reported by the scanner can be displayed using the "\-\-help \-d epson" -parameters to scanimage. +parameters to +.BR scanimage (1).  The -.I \-\-mirror +.B \-\-mirror  option controls the way the image is scanned. By reading the image data  from right to left the image is mirrored. Valid options are "yes" and  "no". The default is "no".  The -.I \-\-speed +.B \-\-speed  option can improve the scan speed in monochrome mode. Valid options are  "yes" or "no", the "yes" option will speed up the scan if this option  is supported.  The -.I \-\-auto\-area\-segmentation +.B \-\-auto\-area\-segmentation  switch activates the automatic area segmentation for monochrome scans. The  scanner will try to determine which areas are text and which contain  images. The image areas will be halftoned, and the text will be  improved. Valid options are "yes" and "no". The default is "yes".  The -.I \-\-gamma\-table +.B \-\-gamma\-table  parameter can be used to download a user defined gamma table. The option  takes 256 values from the range 0-255. In color mode this option equally  affects the red, green, and blue channel.  The -.I \-\-red\-gamma\-table +.B \-\-red\-gamma\-table  parameter can be used to download a user defined gamma table for the  red channel. The valid options are the same as for \-\-gamma\-table.  The -.I \-\-green\-gamma\-table +.B \-\-green\-gamma\-table  parameter can be used to download a user defined gamma table for the  green channel. The valid options are the same as for \-\-gamma\-table.  The -.I \-\-blue\-gamma\-table +.B \-\-blue\-gamma\-table  parameter can be used to download a user defined gamma table for the  blue channel. The valid options are the same as for \-\-gamma\-table.  The color correction coefficients -.I \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9 +.B \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9  will install color correction coefficients for the user defined color  correction. Values are specified as integers in the range \-127..127.  The -.I \-\-preview +.B \-\-preview  option requests a preview scan. The frontend software automatically selects a low  resolution. Valid options are "yes" and "no". The default is "no".  The -.I \-\-preview\-speed +.B \-\-preview\-speed  options will increase the scan speed if this is supported by the  scanner. Valid options are "yes" and "no", the default is "no".  The geometry options -.I \-l \-t \-x \-y -control the scan area: \-l sets the top left x coordinate, \-t the top -left y coordinate, \-x selects the width and \-y the height of the scan -area. All parameters are specified in millimeters. +.B \-l \-t \-x \-y +control the scan area: +.B \-l +sets the top left x coordinate, +.B \-t +the top left y coordinate, +.B \-x +selects the width and +.B \-y +the height of the scan area. All parameters are specified in millimeters.  The -.I \-\-quick\-format +.B \-\-quick\-format  option lets the user select a scan area with predefined sizes. Valid  parameters are "CD", "A5 portrait", "A5 landscape", "Letter", "A4" and  "max". The default is "max", which selects the largest possible area.  The -.I \-\-source +.B \-\-source  option selects the scan source. Valid options depend on the installed  options. The default is "Flatbed".  The -.I \-\-auto\-eject +.B \-\-auto\-eject  option will eject a page after scanning from the document feeder.  The -.I \-\-film\-type +.B \-\-film\-type  option will select the film type for scans with the transparency  unit. This option is only activated if the TPU is selected as scan  source. Valid options are "Negative Film" and "Positive Film".  The -.I \-\-focus\-position +.B \-\-focus\-position  option selects the focus position for all scans. Valid options are "Focus  2.5mm above glass" and "Focus on glass". The focus on the 2.5mm point  above the glass is necessary for scans with the transparency unit, so @@ -222,13 +237,15 @@ will ignore this option.  .SH CONFIGURATION FILE -The configuration file @CONFIGDIR@/epson.conf specifies the device(s) that the -backend will use. Possible connection types are: +The configuration file +.I @CONFIGDIR@/epson.conf +specifies the device(s) that the backend will use. Possible connection types are:  .TP  .I SCSI  This is the default, and if nothing else is specified the backend software will  open a given path as SCSI device. More information about valid syntax for SCSI -devices can be found in sane\-scsi(5). +devices can be found in +.BR sane\-scsi (5).  .br  Usually SCSI scanners are configured with a line "scsi EPSON" in this file. In  some cases it may be necessary to only use the string "scsi" (e.g. for the GT-6500). @@ -279,7 +296,10 @@ only if you know what you are doing!  .SH "SEE ALSO" -sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1) +.BR sane\-scsi (5), +.BR scanimage (1), +.BR xscanimage (1), +.BR xsane (1)  .SH BUGS @@ -302,5 +322,6 @@ Perfection 1260 are not supported by this backend.  .SH AUTHOR -The package is actively maintained by Karl Heinz Kremer (khk@khk.net). The -software is based on work by Christian Bucher and Kazuhiro Sasayama +The package is actively maintained by Karl Heinz Kremer +.RI ( khk@khk.net ). +The software is based on work by Christian Bucher and Kazuhiro Sasayama.  | 