diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2020-08-24 18:44:51 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2020-08-24 18:44:51 +0200 |
commit | ad38bc6ecb80ddeb562841b33258dd53659b1da6 (patch) | |
tree | e02e9c3ff760554fd87f70df0e18b88594091a48 /doc/sane-pixma.man | |
parent | 9c23ed018d72eed2554f4f9cff1ae6e6bb0cd479 (diff) |
New upstream version 1.0.31upstream/1.0.31
Diffstat (limited to 'doc/sane-pixma.man')
-rw-r--r-- | doc/sane-pixma.man | 63 |
1 files changed, 43 insertions, 20 deletions
diff --git a/doc/sane-pixma.man b/doc/sane-pixma.man index ea85ec5..87aadd4 100644 --- a/doc/sane-pixma.man +++ b/doc/sane-pixma.man @@ -1,4 +1,4 @@ -.TH "sane\-pixma" "5" "28 Dec 2019" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" +.TH "sane\-pixma" "5" "15 Aug 2020" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" .IX sane\-pixma .SH NAME sane\-pixma \- SANE backend for Canon Multi-Function Printers and CanoScan Scanners @@ -15,9 +15,9 @@ over IPv4 as well as IPv6 (MFNP over IPv6 is untested). Currently, the following models work with this backend: .PP .RS -PIXMA E510 +PIXMA E410, E510 .br -PIXMA G2000, G2010, G2100 +PIXMA G2000, G2010, G2100, G4000 .br PIXMA MG2100, MG2200, MG2400, MG2500, MG2900, MG3000, MG3100 .br @@ -33,7 +33,7 @@ PIXMA MP210, MP220, MP230, MP240, MP250, MP260, MP270, MP280 .br PIXMA MP360, MP370, MP390 .br -PIXMA MP450, MP460, MP470, MP480, MP490 +PIXMA MP450, MP460, MP470, MP480, MP490, MP495 .br PIXMA MP500, MP510, MP520, MP530, MP540, MP550, MP560 .br @@ -51,7 +51,11 @@ PIXMA MX410, MX420, MX470, MX510, MX520, MX530, MX700, MX720 .br PIXMA MX850, MX860, MX870, MX882, MX885, MX890, MX920, MX7600 .br -PIXMA TS3100, TS5000, TS6100, TS6200, TS8000, TS8200 +PIXMA TR4500 +.br +PIXMA TS3100, TS3300, TS5000, TS5100, TS6100, TS6200, TS8000 +.br +PIXMA TS8200 .br PIXUS MP10 .br @@ -69,11 +73,13 @@ imageCLASS MF5730, MF5770, MF6550, MPC200 .br imageCLASS D420, D480, D530, D570 .br -i-SENSYS MF210, MF230, MF240, MF620, MF630, MF640, MF645C, MF730 +i-SENSYS MF210, MF230, MF240, MF440, MF620, MF630, MF640 +.br +i-SENSYS MF645C, MF730, MF731/733, MF741/743 .br -i-SENSYS MF731/733, MF741/743, MF3010, MF4320d, MF4330d, MF4500 +i-SENSYS MF3010, MF4320d, MF4330d, MF4500, MF4700, MF4800 .br -i-SENSYS MF4700, MF4800, MF6100, MF8030, MF8200C, MF8300 +i-SENSYS MF6100, MF8030, MF8200C, MF8300 .br imageRUNNER 1020/1024/1025, 1133 .br @@ -81,7 +87,7 @@ CanoScan 8800F, 9000F, 9000F Mark II .br CanoScan LiDE 300, 400 .br -MAXIFY MB2000, MB2100, MB2300, MB2700, MB5000, MB5400 +MAXIFY MB2000, MB2100, MB2300, MB2700, MB5000, MB5100, MB5400 .RE .PP The following models are not well tested and/or the scanner sometimes hangs @@ -97,31 +103,31 @@ in the backend so that they get recognized and activated. Feedback in the sane\-devel mailing list welcome. .PP .RS -PIXMA E400, E410, E460, E470, E480, E500, E560, E600, E610 +PIXMA E400, E460, E470, E480, E500, E560, E600, E610 .br PIXMA E3100, E3300, E4200 .br PIXMA MG4100, MG6500, MG6600, MG6800, MG6900, MG8100 .br -PIXMA MP375R, MP493, MP495, MP740 +PIXMA MP375R, MP493, MP740 .br PIXMA MX320, MX390, MX430, MX450, MX490, MX710 .br -PIXMA G3000, G3010, G4000, G4010, G6000, G6080 +PIXMA G3000, G3010, G4010, G6000, G6080, G7000, GM4000 .br -PIXMA TR4500, TR7500, TR7530, TR8500, TR8530, TR8580, TR9530 +PIXMA TR7500, TR7530, TR8500, TR8530, TR8580, TR9530 .br -PIXMA TS5100, TS6000, TS6130, TS6180, TS6230, TS6280, TS6300 +PIXMA TS6000, TS6130, TS6180, TS6230, TS6280, TS6300, TS6330 .br -PIXMA TS6330, TS6380, TS7330, TS8100, TS8130, TS8180, TS8230 +PIXMA TS6380, TS7330, TS8100, TS8130, TS8180, TS8230, TS8280 .br -PIXMA TS8280,, TS8300, TS8330, TS8380, TS9000, TS9100, TS9180 +PIXMA TS8300, TS8330, TS8380, TS9000, TS9100, TS9180, TS9500 .br -PIXMA TS9500, TS9580 +PIXMA TS9580 .br PIXUS MP5, XK50, XK60, XK70, XK80 .br -imageCLASS MF810/820, MF5630, MF5650, MF5750, MF8170c +imageCLASS MF720, MF810/820, MF5630, MF5650, MF5750, MF8170c .br imageCLASS MPC190, D550 .br @@ -129,7 +135,7 @@ i-SENSYS MF110, MF220, MF260, MF410, MF420, MF510, MF520, MF740 .br i-SENSYS MF5880dn, MF5900, MF6680dn, MF8500C .br -MAXIFY MB5100, MB5300 +MAXIFY MB5300 .RE .PP The following models may use partly the same Pixma protocol as other devices @@ -234,10 +240,25 @@ or 1 = JPEG, 2 = TIFF, 3 = PDF, 4 = Compact PDF. For some scanners this value is equivalent to the number of the pressed button. Not all scanners can provide this data. .TP -.I scan-resolution +.I scan\-resolution (read only) Returns the resolution of the scan operation if the scanner provides that data. Known values: 1 = 75 dpi, 2 = 150 dpi, 3 = 300 dpi, 4 = 600 dpi. Not all scanners can provide this data. +.TP +.I document\-type +(read only) Returns the type of the scanned document if the scanner provides +that data. Known values: 1 = Document, 2 = Photo, 3 = Auto scan. Not all scanners +can provide this data. +.TP +.I adf\-status +(read only) Returns the status of the document feeder if the scanner provides +that data. Known values: 1 = ADF empty, 2 = ADF filled. Not all scanners can +provide this data. +.TP +.I adf\-orientation +(read only) Returns the scan orientation of the medium scanned from ADF if the +scanner provides that data. Known values: 1 = Portrait, 2 = Landscape. Not all +scanners can provide this data. .SH FILES .TP .I @LIBDIR@/libsane\-pixma.a @@ -418,6 +439,8 @@ to "/tmp/config:" would result in directories "tmp/config", ".", and .SH "SEE ALSO" .BR sane (7), .BR sane\-dll (5), +.BR scanimage (1), +.BR gamma4scanimage (1), .PP In case of trouble with a recent Pixma model, try the latest code for the pixma backend, available in the Sane git repository at: |