diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/sane-teco2.man |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/sane-teco2.man')
-rw-r--r-- | doc/sane-teco2.man | 229 |
1 files changed, 229 insertions, 0 deletions
diff --git a/doc/sane-teco2.man b/doc/sane-teco2.man new file mode 100644 index 0000000..3abd3b8 --- /dev/null +++ b/doc/sane-teco2.man @@ -0,0 +1,229 @@ +.TH sane\-teco2 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" +.IX sane\-teco2 +.SH NAME +sane\-teco2 \- SANE backend for TECO / RELISYS scanners +.SH DESCRIPTION +The +.B sane\-teco2 +library implements a SANE (Scanner Access Now Easy) backend that +provides access to some TECO SCSI flatbed scanners. This backend +should be considered +.B beta-quality +software! TECO scanners are sold under +various brands like Mustek, Relisys, Piotech, Primax, TRUST. +This backend may or may not support yours. +.PP +The scanners that should work with this backend are: +.PP +.RS +.ft CR +.nf + Vendor Model TECO model status +---------------------- -------------- ----------- + Mustek ScanMagic 4830S VM3575 untested + Primax Jewel 4800 VM356A good + Primax Profi 9600 VM6575 basic + Primax Profi 19200 VM6586 good + Relisys APOLLO Express 3 VM356A basic + Relisys APOLLO Express 6 VM6565 good + Relisys APOLLO Express 12 ? untested + Relisys AVEC II S3 VM3564 good + Relisys AVEC Super 3 VM3575 basic + Relisys SCORPIO Pro VM6575 good + Relisys SCORPIO Pro-S VM6586 untested + Relisys SCORPIO Super 3 VM3575 good +.fi +.ft R +.RE + +For all these scanners, lineart and gray mode work +well. However, most of them do not support more than a handful of +resolutions in color mode. See the backend home page (under AUTHOR) +for the exact status of each scanner. + +Note that the untested scanner will not be directly supported. You +should contact the author for that. + +The TECO VM number can usually be found at the back of the +scanner. It is also part of the FCC ID. + +The options the backend supports can either be selected through +command line options to programs like scanimage or through GUI +elements in xscanimage, xsane, quiteinsane or kooka. + +.br +If you have any success with a scanner not listed here, or if you have +any strange behavior, please report to the backend maintainer or to +the SANE mailing list. + +Valid command line options and their syntax can be listed by using +.RS +scanimage \-\-help \-d teco2 +.RE + +.TP +.B Scan Mode + +.TP +.B \-\-mode +selects the basic mode of operation of the scanner valid choices are +.I Lineart +, +.I Gray +and +.I Color +The Lineart mode is black and white only (1 bit). Gray mode +will produce 256 levels of gray (8 bits). Color will produce a 24 bits +color image. + +.TP +.B \-\-resolution +Lineart and Gray +selects the resolution for a scan. The scanner can do all resolutions +between 1 and 600, in increments of 1. + + +Color +selects the resolution for a scan. The scanner can do only the +resolutions listed. + +All values with ydpi > 300 (300 x 600) or 600 (600 x 1200) result in +a wrong proportion for the scan. The proportion can be adjusted with +the following imagemagick command: +convert \-geometry (dpi/max_xdpi * 100%)x100% +max_xdpi is for the vm3575 constant with 300 dpi +e.g. 600dpi adjust with: convert \-geometry 200%x100% + +.TP +.B Geometry options + +.TP +.B \-l \-t \-x \-y +control the scan area: \-l sets the top left x coordinate, \-t the top +left y coordinate, \-x selects the width and \-y the height of the scan +area. All parameters are specified in millimeters by default. + + +.TP +.B Enhancement options + +.TP +.B \-\-custom\-gamma (no custom gamma option for the VM3564 and VM356A) +(color mode only) allows the user to specify a gamma table (see the +next 3 parameters). + +.TP +.B \-\-red\-gamma\-table +(color mode only) can be used to download a user defined +gamma table for the red channel. The table must be 256 bytes long. + +.TP +.B \-\-green\-gamma\-table +(color mode only) can be used to download a user defined +gamma table for the green channel. The table must be 256 bytes long. + +.TP +.B \-\-blue\-gamma\-table +(color mode only) can be used to download a user defined gamma table +for the blue channel. The table must be 256 bytes long. + +.TP +.B \-\-white\-level\-r +(VM3564, VM356A, VM3575 and VM6575 only) Selects what red radiance level should be +considered "white", when scanning some sheets by changing the calibration +value loaded into the scanner. Scale 0..64 in steps of 1. + +.TP +.B \-\-white\-level\-g +(VM3564, VM356A, VM3575 and VM6575 only) Selects what green radiance level should be +considered "white", when scanning some sheets by changing the calibration i +value loaded into the scanner. Scale 0..64 in steps of 1. + +.TP +.B \-\-white\-level\-b +(VM3564, VM356A, VM3575 and VM6575 only) Selects what blue radiance level should be +considered "white", when scanning some sheets by changing the calibration +value loaded into the scanner. Scale 0..64 in steps of 1. + +.TP +.B \-\-preview +requests a preview scan. The resolution used for that scan is 50 dpi +(for VM356A and VM6575 75 dpi) and the scan area is the maximum allowed. +The scan mode is user selected. The default is "no". + + +.SH CONFIGURATION FILE +The configuration file @CONFIGDIR@/teco2.conf supports only one +information: the device name to use (eg /dev/scanner). + + +.SH FILES +.TP +.I @LIBDIR@/libsane\-teco2.a +The static library implementing this backend. +.TP +.I @LIBDIR@/libsane\-teco2.so +The shared library implementing this backend (present on systems that +support dynamic loading). + + +.SH ENVIRONMENT +.TP +.B SANE_DEBUG_TECO2 +If the library was compiled with debug support enabled, this +environment variable controls the debug level for this backend. E.g., +a value of 128 requests all debug output to be printed. Smaller levels +reduce verbosity. +.TP +.B SANE_TECO2_CAL_ALGO +Either 0 or 1. Selects the algorithm for the calibration. A +value of 1 seems to give better scans on the VM356A, VM3575. +Feedback on it is welcome. +For VM3564, VM356A, VM3575, VM6575 default 1. +For other supported types default 0. + + +.SH LIMITATIONS +The windows TWAIN driver has many more options than this SANE +backend. However they are only software adjustments. This backend only +implements what the scanner can support. + + +.SH BUGS + +Plenty. Parts of this backend are still under development. + + +.SH "SEE ALSO" + +sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7) + + +.SH AUTHORS +.TP +Frank Zago +.I http://www.zago.net/sane/#teco2 +.TP +The package is actively maintained by Gerard Klaver. +.I http://gkall.hobby.nl/teco2.html + + + + +.SH CREDITS + +Thanks to: +.TP +Gerard Klaver for his relentless VM3575 testings and contributed a patch to support the VM3564 and VM356A. +.TP +Mark Plowman for providing the first SCSI traces from a VM3575. +.TP +Andreas Klaedtke for providing the first SCSI traces from a VM6586 and for his testing, and to Stefan von Dombrowski for his testing. +.TP +Nicolas Peyresaubes for providing the first SCSI traces from a VM656A and for his testing. +.TP +Dave Parker for testing the support for the VM6575. +.TP +Michael Hoeller for testing the support for the VM356A. +.TP +Christoph.Hoeffner for testing the support for the VM3564 (Relisys AVEC II S3 firmware 1.09). |