diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2014-10-06 14:00:40 +0200 |
commit | 6e9c41a892ed0e0da326e0278b3221ce3f5713b8 (patch) | |
tree | 2e301d871bbeeb44aa57ff9cc070fcf3be484487 /doc/sane-u12.man |
Initial import of sane-backends version 1.0.24-1.2
Diffstat (limited to 'doc/sane-u12.man')
-rw-r--r-- | doc/sane-u12.man | 184 |
1 files changed, 184 insertions, 0 deletions
diff --git a/doc/sane-u12.man b/doc/sane-u12.man new file mode 100644 index 0000000..8b35fdf --- /dev/null +++ b/doc/sane-u12.man @@ -0,0 +1,184 @@ +.TH sane\-u12 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" +.IX sane\-u12 +.SH NAME +sane\-u12 \- SANE backend for Plustek USB flatbed scanners, +based on older parport designs +.SH DESCRIPTION +The +.B sane\-u12 +library implements a SANE (Scanner Access Now Easy) backend that +provides access to USB flatbed scanners based on Plusteks' ASIC +98003 (parallel-port ASIC) and a GeneSys Logics' USB-parport +bridge chip. + +.SH "SUPPORTED DEVICES" +The backend is able to support some early Plustek USB scanner based +their old parport design around the ASIC 98003 and other rebadged +Plustek devices. The following tables will give you a short overview. + +If your Plustek scanner has another Product ID, then the device is +.B NOT +supported by this backend. +.br + +Vendor Plustek \- ID: 0x07B3 +.br +.ft CR +.nf +---------------------------------------------------------- +Model: Vendor-ID: Product-ID: +---------------------------------------------------------- +OpticPro U12 0x07B3 0x0001 +OpticPro U1212 0x07B3 0x0001 +OpticPro UT12 0x07B3 0x0001 +.fi +.ft R +.PP + +Vendor KYE/Genius +.br +.ft CR +.nf +-------------------------------------------------------- +USB Model: Vendor-ID: Product-ID: +-------------------------------------------------------- +ColorPage Vivid III USB 0x07B3 0x0001 +ColorPage HR6 V1 0x0458 0x2004 +.fi +.ft R +.PP + +.SH "CONFIGURATION" +To use your scanner with this backend, you need at least two +entries in the configuration file +.I @CONFIGDIR@/u12.conf +.RS +.I [usb] vendor-id product-id +.br +.I device /dev/usbscanner +.RE +.PP +.I [usb] +tells the backend, that the following devicename (here +.IR /dev/usbscanner ) +has to be interpreted as USB scanner device. If vendor- and +product-id has not been specified, the backend tries to +detect this by its own. If device is set to +.I auto +then the next matching device is used. +.PP +.B +The Options: +.PP +option warmup t +.RS +.I t +specifies the warmup period in seconds +.RE +.PP +option lampOff t +.RS +.I t +is the time in seconds for switching off the lamps in +standby mode +.RE +.PP +option lOffonEnd b +.RS +.I b +specifies the behaviour when closing the backend, 1 --> switch +lamps off, 0 --> do not change lamp status +.RE + +.PP +See the u12.conf file for examples. +.PP +.B Note: +.br +You have to make sure, that the USB subsystem is loaded +correctly and you have access to the device-node. For +more details see +.B sane\-usb (5) +manpage. You might use +.B sane\-find\-scanner +to check that you have access to your device. +.PP +.B Note: +.br +If there's no configuration file, the backend defaults to +.B device auto + +.SH FILES +.TP +.I @CONFIGDIR@/u12.conf +The backend configuration file +.TP +.I @LIBDIR@/libsane\-u12.a +The static library implementing this backend. +.TP +.I @LIBDIR@/libsane\-u12.so +The shared library implementing this backend (present on systems that +support dynamic loading). + +.SH ENVIRONMENT +.TP +.B SANE_CONFIG_DIR +This environment variable specifies the list of directories that may +contain the configuration file. Under UNIX, the directories are +separated by a colon (`:'), under OS/2, they are separated by a +semi-colon (`;'). If this variable is not set, the configuration file +is searched in two default directories: first, the current working +directory (".") and then in @CONFIGDIR@. If the value of the +environment variable ends with the directory separator character, then +the default directories are searched after the explicitly specified +directories. For example, setting +.B SANE_CONFIG_DIR +to "/tmp/config:" would result in directories "tmp/config", ".", and +"@CONFIGDIR@" being searched (in this order). +.TP +.B SANE_DEBUG_U12 +If the library was compiled with debug support enabled, this +environment variable controls the debug level for this backend. Higher +debug levels increase the verbosity of the output. + +Example: +export SANE_DEBUG_U12=10 + +.SH "SEE ALSO" +.BR sane (7), +.BR sane\-usb (5), +.BR sane\-plustek (5), +.br +.I @DOCDIR@/u12/U12.changes +.br +.I http://www.gjaeger.de/scanner/u12/ + +.SH "CONTACT AND BUG-REPORTS" +Please send any information and bug-reports to: +.br +.B SANE Mailing List +.PP +Additional info and hints can be obtained from our +.br +Mailing-List archive at: +.br +.B http://www.sane\-project.org/mailing\-lists.html +.PP +or directly from the projects' homepage at: +.br +.B http://www.gjaeger.de/scanner/u12/ +.PP +To obtain debug messages from the backend, please set the +environment-variable +.I SANE_DEBUG_U12 +before calling your favorite scan-frontend (i.e. xscanimage). +.br +.B i.e.: export SANE_DEBUG_U12=20 ; xscanimage +.PP +The value controls the verbosity of the backend. + +.SH "KNOWN BUGS & RESTRICTIONS" +* The driver is in alpha state, so please don't expect too much!!! +.PP +* When using libusb, it might be, that the backend hangs. +In that case, reconnect the scanner. |