diff options
Diffstat (limited to 'NEWS')
| -rw-r--r-- | NEWS | 121 | 
1 files changed, 110 insertions, 11 deletions
| @@ -1,5 +1,104 @@  <!-- -*- Mode: markdown -*- --> +## New with 1.0.32 (released 2021-02-14) + +### Backends + +- all backends now respect the `local_only` parameter when `true` is +  passed to `sane_get_devices()` in that they do not actively go out +  looking for networked devices (!502) +- `artec_eplus48u`: fixes configuration for AstraSlim SE (!545) +- `avision`: adds the AV186+ and AV188 as supported (!532) +- `avision`: fixes doubled height issue (#402) +- `avision`: fixes a debug message and compiler warning (!515) +- `canon_dr`: adds support for the DR-C120 and DR-C130 (#175) +- `canon_dr`: adds support for uploading of fine calibration uploads +- `canon_dr`: enables fine calibration for the P-208 +- `canon_dr`: improves DR-C225 support (#431) +- `canon_lide70`: adds support for document scanning on the Canon LiDE +  600(F), thanks to a hardware donation by Georg Sauthoff +- `dll`: fixes a memory leak (!537) +- `epson2`: adds support for the ET-2600 (#395) +- `epson2`: adds autofocus support for devices that support it (!531) +- `epson2`: fixes brightness support for DS-G20000/12000XL (!529) +- `epson2`: fixes an unchecked return value issue (!526) +- `escl`: adds support for brightness, threshold, sharpen and contrast +  options (!527, !528) +- `escl`: adds support for LaserJet FLowMFP M578 and MFP M630 (#424) +- `escl`: adds support for DeskJet 2710, 2723 (!519) and 3760 (!554) +- `escl`: adds support for the PIXMA TS-5351 (!544) and MG5765 (!517) +- `escl`: adds support for the Brother HL-L258DW (!517) +- `escl`: fixes Avahi device discovery (!536) +- `escl`: fixes crashes for devices without a flatbed (!554) +- `escl`: fixes segfaults in option handling (!557) +- `escl`: fixes sleep mode (!577) +- `escl`: fixes builds without libpoppler-glib-dev (#422) +- `escl`: fixes a memory issue in its capability handling (#425) +- `fujitsu`: fixes brightness/contrast for the iX500 +- `fujitsu`: fixes memory corruption for duplex scans +- `genesys`: disables support for CanoScan 4400F to prevent possible +  physical damage (#436) +- `gt68xx`: fixes scan cancellation logic (#356) +- `pixma`: adds untested support for models released in 2020 (!553) +- `pixma`: adds support for ADF scans on the i-SENSYS MF260 +- `pixma`: adds support for PIXMA M340 buttons and ADF status (!513) +- `pixma`: adds an option to control when to calibrate (#321) +- `pixma`: fixes support for the MX492 (!548) +- `pixma`: fixes ADF support for the MX490 Series +- `pixma`: fixes max resolution for ADF scans on the PIXMA M320 (#364) +- `pixma`: fixes compile errors when libxml2 is not available (#345) +- `plustek`: fixes CanoScanN650u discovery (#137) +- `test`: fixes several memory leaks (!537) + +### Frontends + +- `saned`: add support for listening on a custom or ephemeral port via +  a new `-p`/`--port` option (!549) +- `scanimage`: fixes crashes for multi-pass and handheld scans (#408) +- `scanimage`: fixes a memory leak (!551) +- `scanimage`: fixes option handling for non-compliant backends (#362) + +### Documentation + +- updates our copy of the GPL with the FSF's current postal address. +  This changes references to the Library GPL (LGPL-2.0) into refs to +  the Lesser GPL (LGPL-2.1) but does *not* affect the licensing of our +  backends (#320). +- source code now points to the Free Software Foundation's website for +  copies of the GPL and LGPL (#320) +- updates translations for British English and Ukrainian +- adds a pointer to our Ubuntu PPA for pre-built binaries +- adds SCSI IDs for the EPSON Perfection 1640SU (!509) +- fixes a boat-load of spelling mistakes (!516, thanks @marschap) +- updates description files for `scangearmp2` and `utsushi` external +  backends + +### Build + +- removes support for `automake` maintainer mode (!522) +- removes `sane` subdirectory from the lock directory to fix issues +  when the lock directory is on `tmpfs` (#363) +- adds support for builds using GitLab "source" tarballs (#248) +- fixes static link scenarios (#124) +- fixes `python` invocations to use the detected program (!525) +- disables `genesys` testsuite when that backend is not built (#354) +- suppresses warnings about obsolete autoconf macros (#122) +- fixes availability of sane-backends.pot file inputs (#344) +- fixes `configure.ac` for use with `autoconf-2.70` (#409) +- removes CVS keywords from the source to ease use by downstreams that +  still use CVS (!547) + +### Miscellaneous + +- `udev` rules now trigger on all events other than `remove` (!541). +  This aims to address a kernel API change introduced in 4.14.  The +  new behaviour may slow down `udev`'s processing of kernel events +  when still using our plain `udev` or `udev+acl` rules, even though +  these have been optimized slightly (#341).  If that bothers you, now +  is a good time to switch to our `udev+hwdb` rules in combination +  with the `hwdb` database if you have not done so already. + +  ## New with 1.0.31 (released 2020-08-23)  ### Backends @@ -44,7 +143,7 @@  - adds and updates information for multiple supported and unsupported    devices  - translation updates for British English, French, German, Italian and -  Ukranian +  Ukrainian  - `scanimage`: documents the JPEG compression level  - minor improvements documenting build requirements @@ -56,7 +155,7 @@    required support is not available, `configure` will exit with an    error.  - improves checking for libjpeg version dependent requirements -- has been made reproducable (#228) +- has been made reproducible (#228)  - fixes build issues on MinGW  ### Miscellaneous @@ -338,7 +437,7 @@ New with 1.0.18, released 2006-07-02:    microtek2, mustek_pp, niash, plustek, snapscan, sp15c, test, u12, umax1220u.  * Scanimage batch mode fixes.  * Scanner lists contain USB vendor/product ids and some statistics now. -* Udev/hotplug lists are generated autmatically from the .desc files now. +* Udev/hotplug lists are generated automatically from the .desc files now.  * Portability fixes (especially for DragonFlyBSD and HP/UX).  * Build system updates.  * Updated translations. @@ -414,7 +513,7 @@ New with 1.0.14, released 2004-05-01:  New with 1.0.13, released 2003-11-22:  * New backends: mustek_pp_ccd (for Mustek parport CCD scanners), -  plustek_pp (for Plustek parport scanners, splitted from the plustek backend). +  plustek_pp (for Plustek parport scanners, split from the plustek backend).  * Updated backends: avision, canon630u, coolscan, epson, fujitsu, gphoto2,    gt68xx, hp, hp5400, mustek, mustek_pp, pie, plustek, snapscan, teco2, test,    umax, umax_pp. @@ -484,7 +583,7 @@ New with 1.0.9, released 2002-10-24:  * New tool to create gamma tables (gamma4scanimage).  * Support for ICC profiles for scanimage.  * USB scanner should work on all systems supported by libusb now. -* Portability fixes (especially for big-endian sytems, Irix, OpenStep, OS/2, +* Portability fixes (especially for big-endian systems, Irix, OpenStep, OS/2,    Solaris).  * New and updated translations for various backends.  * New system for generating lists of manufacturers/backends. @@ -548,7 +647,7 @@ New with 1.0.6, released 2001-11-05:  New with 1.0.5, released 2001-07-01:  * New backends: bh (Bell+Howell Copiscan II series), dc240 (Kodak DC240 -  Digital Camera), sm3600 (Microtek ScanMaker 3600), umax_pp (Umax paralell +  Digital Camera), sm3600 (Microtek ScanMaker 3600), umax_pp (Umax parallel    port scanners).  * Updated backends: artec (v0.5.16), dc25 (v1.2), dll (v1.0.3),    epson (v0.2.08), hp (v0.94), microtek (v0.12.3), microtek2(v0.9), @@ -577,7 +676,7 @@ New with 1.0.4, released 2000-12-21:    hp (v0.93), mustek (v1.0-102), mustek_pp (v0.9-devel), plustek (v0.38),    sharp (v0.32), umax (v1.0-21).  * Moved frontends xscanimage and xcam to a new package (sane-frontends). -* Added authentification with encrypted passwords. +* Added authentication with encrypted passwords.  * Installation of shared libraries on AIX is supported now.  * Fixed compilation bugs on Irix and FreeBSD.  * Better debug output on platforms not supporting vararg macros. @@ -685,7 +784,7 @@ New with 1.01:     o larger buffer acquired (speeds up scanning slightly)     o for SE models minimal resolution increased from 60 dpi to 75 dpi     o for SE models 75 dpi in color mode is no longer used as the newer -     firware version seems to be even more buggy +     firmware version seems to be even more buggy     o bug in calculation of gamma table corrected (applies only to SE models,       NOT related to the overflow problem which was corrected via CLIP( ) )     o default resolution is now set according to the minimal resolution @@ -894,7 +993,7 @@ New with 0.74:   o changed the default for the resolution   o The values for the SANE_Params struct are calculated more precisely   o dito the number of scan lines that fit into the frontend buffer - o changed some return stati ( replaced SANE_STATUS_INVAL with + o changed some return statuses ( replaced SANE_STATUS_INVAL with     SANE_STATUS_IO_ERROR where the first one is not allowed)   o completely rewrote the end of scan and cancel scan handling   o fixed another bug that caused xscanimage to crash with sigsegv @@ -913,7 +1012,7 @@ New with 0.74:    o Quality calibration / calibration by driver now works for same scanners.       - added selection for type of shading data calculation    o Solved problem with black area at top of the image -    (happend only with some SCSI-adapters). +    (happened only with some SCSI-adapters).    o Added gamma download format type 0 and type 1 for older scanners.    o Added Astra 1220S as supported scanner:       - added 36 gamma input bits support for Astra 1220S @@ -969,7 +1068,7 @@ New with 0.73:         - 3-pass scanners         - more than 8 bit per color output data. Provisions are made here           and there in the code, to support more than 8 bit, but that's -         uncomplete. +         incomplete.  * configure --disable-static should now work as expected. | 