summaryrefslogtreecommitdiff
path: root/backend/canon_pp.h
diff options
context:
space:
mode:
Diffstat (limited to 'backend/canon_pp.h')
-rw-r--r--backend/canon_pp.h125
1 files changed, 125 insertions, 0 deletions
diff --git a/backend/canon_pp.h b/backend/canon_pp.h
new file mode 100644
index 0000000..4797924
--- /dev/null
+++ b/backend/canon_pp.h
@@ -0,0 +1,125 @@
+/* sane - Scanner Access Now Easy.
+ Copyright (C) 2001-2002 Matthew C. Duggan and Simon Krix
+ This file is part of the SANE package.
+
+ This program is free software; you can redistribute it and/or
+ modify it under the terms of the GNU General Public License as
+ published by the Free Software Foundation; either version 2 of the
+ License, or (at your option) any later version.
+
+ This program is distributed in the hope that it will be useful, but
+ WITHOUT ANY WARRANTY; without even the implied warranty of
+ MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
+ General Public License for more details.
+
+ You should have received a copy of the GNU General Public License
+ along with this program; if not, write to the Free Software
+ Foundation, Inc., 59 Temple Place - Suite 330, Boston,
+ MA 02111-1307, USA.
+
+ As a special exception, the authors of SANE give permission for
+ additional uses of the libraries contained in this release of SANE.
+
+ The exception is that, if you link a SANE library with other files
+ to produce an executable, this does not by itself cause the
+ resulting executable to be covered by the GNU General Public
+ License. Your use of that executable is in no way restricted on
+ account of linking the SANE library code into it.
+
+ This exception does not, however, invalidate any other reasons why
+ the executable file might be covered by the GNU General Public
+ License.
+
+ If you submit changes to SANE to the maintainers to be included in
+ a subsequent release, you agree by submitting the changes that
+ those changes may be distributed with this exception intact.
+
+ If you write modifications of your own for SANE, it is your choice
+ whether to permit this exception to apply to your modifications.
+ If you do not wish that, delete this exception notice.
+
+ -----
+
+ canon_pp.h: $Revision$
+
+ This file is part of the canon_pp backend, supporting Canon FBX30P
+ and NX40P scanners
+
+*/
+
+
+#ifndef CANON_PARALLEL_H
+
+#define CANON_PARALLEL_H
+
+#ifdef BACKEND_NAME
+#undef BACKEND_NAME
+#define BACKEND_NAME canon_pp
+#endif
+
+#define DEBUG_NOT_STATIC
+#include "../include/sane/sanei_debug.h"
+
+#ifndef PACKAGE
+#define PACKAGE "Canon Parallel SANE Backend"
+#endif
+
+#define CMODE_COLOUR "Colour"
+#define CMODE_MONO "Mono"
+#define CANONP_CONFIG_FILE "canon_pp.conf"
+/* options: num,res,colour,depth,tl-x,tl-y,br-x,br-y,cal */
+/* preview option disabled */
+#define NUM_OPTIONS 9
+#define BUF_MAX 64000
+
+/* Indexes into options array */
+#define OPT_NUM_OPTIONS 0
+#define OPT_RESOLUTION 1
+#define OPT_COLOUR_MODE 2
+#define OPT_DEPTH 3
+#define OPT_TL_X 4
+#define OPT_TL_Y 5
+#define OPT_BR_X 6
+#define OPT_BR_Y 7
+#define OPT_CAL 8
+#define OPT_PREVIEW 9
+#if 0
+#define OPT_GAMMA_R 10
+#define OPT_GAMMA_G 11
+#define OPT_GAMMA_B 12
+#endif
+/*#define OPT_GAMMA 13*/
+
+typedef struct CANONP_Scanner_Struct CANONP_Scanner;
+
+struct CANONP_Scanner_Struct
+{
+ CANONP_Scanner *next;
+ SANE_Device hw;
+ SANE_Option_Descriptor opt[NUM_OPTIONS];
+ SANE_Int vals[NUM_OPTIONS];
+ SANE_Bool opened;
+ SANE_Bool scanning;
+ SANE_Bool sent_eof;
+ SANE_Bool cancelled;
+ SANE_Bool setup;
+ SANE_Int lines_scanned;
+ SANE_Int bytes_sent;
+
+ char *weights_file;
+ SANE_Bool cal_readonly;
+ SANE_Bool cal_valid;
+
+ scanner_parameters params;
+ scan_parameters scan;
+
+ int ieee1284_mode;
+ int init_mode;
+
+ SANE_Bool scanner_present;
+
+};
+
+
+#endif
+