diff options
Diffstat (limited to 'doc/plustek/Plustek-USB.changes')
-rw-r--r-- | doc/plustek/Plustek-USB.changes | 307 |
1 files changed, 307 insertions, 0 deletions
diff --git a/doc/plustek/Plustek-USB.changes b/doc/plustek/Plustek-USB.changes new file mode 100644 index 0000000..8ed5cc8 --- /dev/null +++ b/doc/plustek/Plustek-USB.changes @@ -0,0 +1,307 @@ +Plustek.changes - Gerhard Jaeger <gerhard@gjaeger.de> +===================================================== + +Note: All other not mentioned builds have never been released. + +V 0.52-11 (2013-02-13) +--------------------- +Added support for Q-Scan A6 scanner (see report #312073) + +V 0.52-10 (2012-03-19) +--------------------- +Fixed batch scanning + +V 0.52-9 (2009-04-27) +--------------------- +Tweaked highspeed settings for Epson 1260 + +V 0.52-8 (2008-08-25) +--------------------- +Added preliminary support for Visioneer XP100 +Tweaked entry for LM9831 version of Plustek UT12 + +V 0.52-7 (2007-12-13) +--------------------- +Fixed alignment issues for archs like XScale/ARM +Fixed dumppic function to get valid grayscale pictures + +V 0.52-6 (2007-11-23) +--------------------- +Tweaked TravelScan464 settings. +Improved AFE gain calculation for CIS devices. This should avoid +stripes in the scanned images. + +V 0.52-4 (2007-11-16) +--------------------- +Tweaked TravelScan464 settings +Added possibility to disable dark-calibration with lamp on +(touches devices like CanoScan1220 etc) +Use attribute packed for data access structs + +V 0.52-4 (2007-11-07) +--------------------- +Added support for Syscan TravelScan464 + +V 0.52-3 (2007-07-26) +--------------------- +Checked UMAX3400/3450 models +Force output bit set (MIO), when lamp is switched + +V 0.52-2 (2007-07-10) +--------------------- +Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does +not seem to support 14-bit modes. + +V 0.52-1 (2007-06-29) +--------------------- + +Added sheetfed device Q-Scan USB001 from Portable Peripherals +Fixed Mustek Bearpaw and did some speedup (bugreports #304343 and +#301763) +Fixed calibration for senororders other that RGB + +V 0.51-16 (2007-03-05) +---------------------- + +Added CanoScan to all Canon device strings. +Identified one more Plustek device as U24. +Fixed button handling for Plustek/KYE devices and +added some more debug messages. + +V 0.51-15 (2006-11-22) +---------------------- +Fixed option descriptors (bugreport #303786) + +V 0.51-14 (2006-08-11) +---------------------- +Lowered speed for LiDE20/30 models in low resolution mode (<75dpi) + +V 0.51-13 (2006-08-09) +---------------------- +Changed sane.type to "flatbed scanner" only +Fixed motorsettings for LiDE30 (bugreport #303722) +Fixed LiDE20 settings. Got some reports of non-working devs, although +my N670U is working fine. Lowered the max speeds and increased the +MCLK-div for fast movement. (bugreport #303695) + +V 0.51-12 (2006-06-30) +---------------------- +Fixed bit-depth selection + +V 0.51-11 (2006-06-08) +---------------------- +Fixed calibration: All modes will be coarse calibrated now, fine calibration +will be done only for 8 bit modes. +Fixed paper eject during startup. + +V 0.51-10 (2006-05-28) +--------------------- +Released + +V 0.51-8 (2006-04-09) +--------------------- +Added cache for fine calibration (CIS devices only) +Added support for sheet-fed scanner (CIS devices only) +Added support for Syscan TravelScan662 + +V 0.50-10 (2006-01-31) +--------------------- +Fixed CanoScan N1220U settings. + +V 0.50-9 (2006-01-19) +--------------------- +Added high-speed setting for HP2200. +Fixed constraint_type for OPT_BUTTON. + +V 0.50-8 (2006-01-18) +--------------------- +Fixed CanoScan N670U settings (bugreport #302433). + +V 0.50-7 (2005-10-28) +--------------------- +Changed high-speed setting for UMAX 3400, due to bugreport #302317. +Added disable speeup feature (as option). +Fixed CanoScan N650U settings (bugreport #302433). + +V 0.50-6 (2005-10-25) +--------------------- +Fixed segfault in fine calibration for CIS devices. +Tweaked LiDE25 settings (thanks to Gerd Cendelin for lending me +his LiDE25). +Let 1200DPI CIS devices use now the green-channel for gray scans. + +V 0.50-5 (2005-10-21) +--------------------- +Fixed high-speed feature of CanoScan D660U. + +V 0.50-4 (2005-10-02) +--------------------- +Updated motor settings for Canoscan LiDE25, thanks to +Stephan February <stephanf@singnet.com.sg> for providing these +values. + +V 0.50-3 (2005-08-22) +--------------------- +Fixed problem, when trying to scan at resolutions beyond the +optical one (sensor stops too early) + +V 0.50-2 (2005-08-19) +--------------------- +More cleanup. +Removed obsolete _WAF_BLACKFINE. +LiDE20 does not seem to have a reliable black calibration area, +so the devices now will switch off the lamp for dark calibration. +Fixed line statistics and added calibration data output. + +V 0.50-1 (2005-08-15) +--------------------- +Cleanup +Activated IPC between reader-process and parent +Added button support for Plustek/Genius devices +Did some whitespace cleanup and removed those *p typedefs +Tried to improve CIS calibration (somewhat back to 1.0.13) +Added _TWEAK_GAIN definition to allow CIS calibration increase +gain values during basic lamp setup phase +Added call to speedtest to CIS calibration +Fixed CanoScan startup problem (the way misc I/Os will be set +after power-up has done the trick) + +V 0.49-8 (2005-08-08) +--------------------- +Added LiDE25 settings + +V 0.49-7 (2005-07-21) +--------------------- +Bugfix release - fixed lampsettings for CIS calibration + +V 0.49-6 (2005-07-07) +--------------------- +Bugfix release - calibration and segfault :( + +V 0.49-5 (2005-07-04) +--------------------- +Added IPC between reader-process and parent process to +be pepared for sharing calibration info. +Added button support for backend + +V 0.49-4 (2005-06-27) +--------------------- +Fixed "double free" problem during sane_exit. + +V 0.49-3 (2005-04-18) +--------------------- +Fixed backtracking problem, when sensor-speedup is active. + +V 0.49-2 (2005-01-12) +--------------------- +Tweaked some device settings +Updated copyright info +Using now PhyDpi.y as selector for the motor MCLK range + +V 0.49-1 (2004-11-19) +--------------------- +Improved multi-device capability + +V 0.48-10 (2004-10-30) +---------------------- +- Fixed a bug in buffer calculation for CIS devices + +V 0.48-9 (2004-10-19) +--------------------- +- Use the same option names for RGB gain as umax_pp backend + +V 0.48-8 (2004-10-06) +--------------------- +- split scanmodes & bit-depths + +V 0.48-7 (2004-10-04) +--------------------- +- changed some strings according to bug #300963 + +V 0.48-6 (2004-09-07) +--------------------- +- fixed UMAX lamp-off bug + +V 0.48-4 (2004-07-26) +--------------------- +- added speedup parameters for UMAX3400/3450 +- added disableSpeedup option +- added UMAX3400/3450 TPA autodetection + +V 0.48-3 (2004-07-16) +--------------------- +- improved autowarmup feature +- improved speedup feature + +V 0.48-2 (2004-07-07) +--------------------- +- fixed binary mode for CanoScan D660U + +V 0.48-1 (2004-07-02) +--------------------- +- added more options to the frontend interface +- added UMAX 3400 with product ID 0x0050 +- added support for the UMAX 3450 +- added autowarmup for CFL (most CCD-scanner) +- added speedup for sensor for some devices +- fixed lamp switching problem for D660U +- fixed negative scanning lamp problem +- fixed Gray 16 mode for CanoScan D660U +- code cleanup + +V 0.47-11 (2004-04-21) +---------------------- +- minor fixes, esp. for MacOSX +- added lamp-off and warmup options to be configurable by backends + +V 0.47-8 - 0.47-10 +------------------ +- never released + +V 0.47-7 (2004-02-08) +--------------------- +- fixed bypass calibration function for CIS devices +- added lampoff stuff to config file + +V 0.47-6 (2004-01-21) +--------------------- +- Cleanup work +- Changed lamp off timer for non-setitimer systems + +V 0.47-5 (2004-01-09) +--------------------- +- Added big-endian code to support also PPC architectures +- Added mov (model override) to support various devices using + the same product ID (namely Mustek BearPaw 1200) +- Added per-model gamma values +- Fixed a bug in the coarse CIS-lamp calibration +- Cleanup work + +V 0.47-1 - 0.47-4 +----------------- +- never released + +V 0.46-9 (2003-11-03) +--------------------- +- Added alternate calibration for CIS devices +- Added coarse calibration data-cache +- Moved parallelport code to extra backend file plustek_pp +- Fixed some minor bugs +- Fixed problem with CIS devices using FreeBSD + +V 0.46-1 - 0.46-8 +----------------- +- never released + +V 0.45 (2003-08-05) +------------------- +- Starting this changelog +- Updates since V 0.44: + * better CIS device support + * added CanoScan N1220U, N1240U + * made CanoScan N650U and N670U work + * fixed EPSON 1260 motor killer-bug + * improved TPA scanning + * fixed TPA warmup bug on EPSON 1260/Photo + * fixed Genius device detection problem + * Added Compaq S4-100 (identical to UMAX3400) |