diff options
Diffstat (limited to 'doc/sane-artec_eplus48u.man')
| -rw-r--r-- | doc/sane-artec_eplus48u.man | 55 | 
1 files changed, 37 insertions, 18 deletions
diff --git a/doc/sane-artec_eplus48u.man b/doc/sane-artec_eplus48u.man index 7e7ec37..70f4254 100644 --- a/doc/sane-artec_eplus48u.man +++ b/doc/sane-artec_eplus48u.man @@ -17,14 +17,19 @@ the scan area.  .PP  If you own a scanner other than the ones mentioned on the list that works with this  backend, please let us know this by sending the scanner's exact model name and -the USB vendor and product ids (e.g. from /proc/bus/usb/devices, -sane\-find\-scanner or syslog) to me. Even if the scanner's name is only +the USB vendor and product ids (e.g. from +.IR /proc/bus/usb/devices , +.BR sane\-find\-scanner (1) +or syslog) to me. Even if the scanner's name is only  slightly different from the models mentioned above, please let me know.  .PP  .SH KERNEL ISSUES  If libusb-0.1.6 or later is installed, this section can be skipped. The -scanner should be found by sane\-find\-scanner without further actions. For -setting permissions and general USB information look at sane\-usb(5). +scanner should be found by +.BR sane\-find\-scanner (1) +without further actions. For setting permissions and general USB information +look at +.BR sane\-usb (5).  .PP  When you are using the scanner module, a Linux kernel 2.4.12 or newer is  required. @@ -32,11 +37,16 @@ required.  .SH FIRMWARE FILE  You need a firmware file for your scanner. That's a small file containing  software that will be uploaded to the scanner's memory. For the scanners -mentioned above, it's usually named Artec48.usb or 1200.usb. You can find it on -the installation CD that was provided by the manufacturer, normally in the -directory Win98, WinMe or similar. If the Windows-driver is installed on your -computer, then you can also find the firmware file under -c:\\windows\\system32\\drivers. +mentioned above, it's usually named +.I Artec48.usb +or +.IR 1200.usb . +You can find it on the installation CD that was provided by the manufacturer, +normally in the directory Win98, WinMe or similar. +If the Windows-driver is installed on your computer, then you can also +find the firmware file under +.IR c:\\windows\\system32\\drivers . +  .SH CONFIGURATION  The contents of the  .I artec_eplus48u.conf @@ -105,13 +115,18 @@ contain the configuration file.  Under UNIX, the directories are  separated by a colon (`:'), under OS/2, they are separated by a  semi-colon (`;').  If this variable is not set, the configuration file  is searched in two default directories: first, the current working -directory (".") and then in /usr/local/etc/sane.d.  If the value of the -environment variable ends with the directory separator character, then -the default directories are searched after the explicitly specified -directories.  For example, setting +directory (".") and then in +.IR @CONFIGDIR@ . +If the value of the environment variable ends with the directory +separator character, then the default directories are searched after +the explicitly specified directories. For example, setting  .B SANE_CONFIG_DIR -to "/tmp/config:" would result in directories "tmp/config", ".", and -"/usr/local/etc/sane.d" being searched (in this order). +to "/tmp/config:" would result in directories +.IR tmp/config , +.IR . , +and +.I @CONFIGDIR@ +being searched (in this order).  .TP  .B SANE_DEBUG_ARTEC_EPLUS48U  If the library was compiled with debug support enabled, this @@ -122,15 +137,19 @@ Example:  export SANE_DEBUG_ARTEC_EPLUS48U=3  .SH "SEE ALSO" -sane(7), sane\-usb(5) +.BR sane (7), +.BR sane\-usb (5)  .SH AUTHOR -Michael Herder +Michael Herder.  .br  This backend is based on the gt68xx test-program written by Sergey Vlasov, Andreas Nowack, and  David Stevenson. Thanks to everyone who tested the backend or reported bugs.  .br -This man page is based on man sane\-gt68xx, written by Henning Meier-Geinitz. +This man page is based on man +.BR sane\-gt68xx (5), +written by Henning Meier-Geinitz. +  .SH BUGS  This backend has been tested on Linux only. If you are using it on a different platform, please  contact us.  | 
