1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
|
.TH sane\-mustek_pp 5 "13 Jul 2008"
.de EX
.sp
.nf
.ft CW
..
.de EE
.ft R
.fi
.sp
..
.IX sane\-mustek_pp
.SH NAME
sane\-mustek_pp \- SANE backend for Mustek parallel port flatbed scanners
.SH DESCRIPTION
The
.B sane\-mustek_pp
library implements a SANE (Scanner Access Now Easy) backend that
provides access to Mustek parallel port flatbed scanners and OEM versions.
There are 2 classes of Mustek parallel port scanners: regular
.B CCD
(cold cathode device) scanners and
.B CIS
(contact image sensor) scanners.
.P
The current version of this backend supports both CCD type scanners and
CIS type scanners.
.P
The following scanners might work with this backend:
.SS "CCD scanners"
.EX
Model: ASIC ID: CCD Type: works:
--------------------------------------------------------------
SE 6000 P 1013 00 yes
SM 4800 P 1013/1015 04/01 yes
SE 1200 ED Plus 1015 01 no
SM 1200 ED Plus 1015 01 no
SE 12000 P 1505 05 no
600 III EP Plus 1013/1015 00/01 yes
SE 600 SEP 1013 ?? yes
600 II EP ???? ?? no
MD9848 1015 00 yes
Gallery 4800 ???? ?? yes
Viviscan Compact II 1013 00 yes
.EE
.SS CIS scanners
.EX
Model: ASIC ID: works:
-----------------------------------------------
Mustek 600 CP & 96 CP 1015 yes (*)
Mustek 1200 CP 1015 yes
Mustek 1200 CP+ 1015 yes
.EE
.EX
OEM versions Original works
--------------------------------------------------
Medion/LifeTec/Tevion
MD/LT 9350/9351 1200 CP yes
MD/LT 9850/9851 1200 CP maybe (**)
MD/LT 9858 1200 CP probably
MD/LT 9890/9891 1200 CP yes
Targa
Funline TS12EP 1200 CP yes
Funline TS6EP 600 CP yes
Trust
Easy Connect 9600+ 600 CP yes
Cybercom
9352 1200 CP yes (***)
.EE
.HP
(*) Calibration problems existed with earlier version of
this driver. They seem to be solved now.
.HP
(**) Problems have been reported in the past for the
MD/LT9850 type (striped scans, head moving in wrong
direction at some resolutions). It is not known whether
the current version of the driver still has these problems.
.PP
.B IF YOU HEAR LOUD CLICKING NOISES, IMMEDIATELY UNPLUG THE SCANNER !
(This holds for any type of scanner).
.HP
(***) Possibly, the engine_delay parameter has to be set to 1 ms
for accurate engine movements.
.PP
Please note that this backend is still under construction. Certain models
are currently not supported and some may never be because the communication
protocol is still unknown (eg., SE 12000 P).
.PP
Some scanners work faster when
.B EPP/ECP
is enabled in the BIOS. EPP mode however may lead to hard-locks on some Linux
systems. If that is the case for you, you can either disable ECP/EPP in your
BIOS or disable it in the backend itself (see GLOBAL OPTIONS).
.PP
Note that the backend needs to run as root or has to have appropriate access
rights to
.I /dev/parport*
if libieee1284 support is compiled in. To allow user
access to the scanner run the backend through the network interface (see
.BR saned (8)
and
.BR sane\-net (5)).
Note also that the backend
.I does not
support
.IR "parport sharing" ,
i.e. if you try printing while scanning, your computer may crash. To enable
parport sharing, you have to enable
.BR libieee1284 (3)
at compile time.
You may also have to enable the backend explicitly in your
.IR dll.conf .
Just remove the hash mark in the line "mustek_pp".
.SH "DEVICE DEFINITION"
This backend allows multiple devices being defined and configured via the
.I mustek_pp.conf
file (even simultaneously, provided that they are connected to different
parallel ports). Please make sure to edit this file
.B before
you use the backend.
.PP
A device can be defined as follows:
.PP
.RS
.I scanner <name> <port name> <driver>
.RE
.PP
where
.HP
.B <name>
is an arbitrary name for the device, optionally enclosed by double quotes,
for instance "LifeTec 9350".
.HP
.B <port name>
is the name of the parallel port to which the device is connected. In case
libieee1284 is used for communication with the port
.I (default
.IR setup) ,
valid port names are
.BR parport0 ,
.BR parport1 ,
and
.BR parport2 .
.PP
In case the backend is configured for raw IO
.I (old
.IR setup) ,
port addresses have to be used instead of port names:
.BR 0x378 ,
.BR 0x278 ,
or
.BR 0x3BC .
The mapping of parallel ports (lp0, lp1, and lp2) to these addresses
can be different for different Linux kernel versions. For instance,
if you are using a Kernel 2.2.x or better and you have only one
parallel port, this port is named lp0 regardless of the base address. However,
this backend requires the base address of your port. If you are not sure which
port your scanner is connected to, have a look at your
.IR /etc/conf.modules ,
.I /etc/modules.conf
and/or
.IR /proc/ioports .
.PP
If you are unsure which port to use, you can use the magic value
.BR *
to probe for your scanner.
.PP
.HP
.B <driver>
is the driver to use for this device. Currently available drivers are:
.IP
.BR cis600 " : for 600 CP, 96 CP & OEM versions"
.br
.BR cis1200 " : for 1200 CP & OEM versions"
.br
.BR cis1200+ " : for 1200 CP+ & OEM versions"
.br
.BR ccd300 " : for 600 IIIE P & OEM version"
.IP
.B Choosing the wrong driver can damage your scanner!
.br
Especially, using the 1200CP settings on a 600CP can be
harmful. If the scanner starts making a loud noise, turn
it off immediately !!!
.PP
Using the cis600 driver on a 1200CP or a 1200CP+ is probably not
dangerous. The cis1200+ driver also works for the 1200CP, and using
the cis1200 driver on a 1200CP+ will typically result in scans that
cover only half of the width of the scan area (also not dangerous).
.PP
If unsure about the exact model of your OEM version, check the optical
resolution in the manual or on the box: the 600CP has a maximum optical
resolution of 300x600 DPI, whereas the 1200CP and 1200CP+ have a maximum
optical resolution of 600x1200 DPI.
.PP
Examples:
.PP
.RS
scanner "LifeTec 9350" 0x378 cis1200
.PP
scanner Mustek_600CP 0x378 cis600
.PP
scanner Mustek_600IIIEP * ccd300
.RE
If in doubt which port you have to use, or whether your scanner is
detected at all, you can use
.I sane\-find\-scanner \-p
to probe all configured ports.
.SH CONFIGURATION
.PP
The contents of the
.I mustek_pp.conf
file is a list of device definitions and device options that correspond to
Mustek scanners. Empty lines and lines starting with a hash mark (#) are
ignored. Options have the following format:
.PP
.RS
.I option <name> [<value>]
.RE
.PP
Depending on the nature of the option, a value may or may not be present.
Options always apply to the scanner definition that precedes them. There
are no global options. Options are also driver-specific: not all drivers
support all possible options.
.SS Common options
.TP
.B bw <value>
Black/white discrimination value to be used during lineart scanning. Pixel
values below this value are assumed to be black, values above are
assumed to be white.
.br
Default value: 127
.br
Minimum: 0
.br
Maximum: 255
.sp
Example: option bw 150
.SS CIS driver options
.TP
.B top_adjust <value>
Vertical adjustment of the origin, expressed in millimeter (floating point).
This option can be used to calibrate the position of the origin, within
certain limits. Note that CIS scanners are probably temperature sensitive, and
that a certain inaccuracy may be hard to avoid. Differences in offset between
runs in the order of 1 to 2 mm are not unusual.
.br
Default value: 0.0
.br
Minimum: \-5.0
.br
Maximum: 5.0
.br
.sp
Example: option top_adjust \-2.5
.TP
.B slow_skip
Turns fast skipping to the start of the scan region off. When the region to
scan does not start at the origin, the driver will try to move the scanhead
to the start of the scan area at the fastest possible speed. On some models,
this may not work, resulting in large inaccuracies (up to centimeters).
By setting this option, the driver is forced to use normal speed during
skipping, which can circumvent the accuracy problems. Currently, there are
no models for which these inaccuracy problems are known to occur.
.sp
By default, fast skipping is used.
.sp
Example: option slow_skip
.TP
.B engine_delay <value>
Under normal circumstances, it is sufficient for the driver to wait for the
scanner signaling that the engine is stable, before a new engine command can
be transmitted. In rare cases, certain scanners and/or parallel port chipsets
appear to prevent reliable detection of the engine state. As a result, engine
commands are transmitted too soon and the movement of the scanner head becomes
unreliable. Inaccuracies ranging up to 10 cm over the whole vertical scan
range have been reported. To work around this problem, the engine_delay option
can be set. If it is set, the driver waits an additional amount of time after
every engine command, equal to the engine_delay parameter, expressed in
milliseconds. It practice an engine_delay of 1 ms is usually sufficient. The
maximum delay is 100 ms.
.sp
Note that every additional ms of delay can add up to 14 seconds to the total
scanning time (highest resolution), so an as small as possible value is
preferred.
.sp
Default value: 0
.br
Minimum: 0
.br
Maximum: 100
.sp
Example: option engine_delay 1
.SS CCD driver options
.TP
.B top <value>
Number of scanlines to skip to the start of the scan area. The number can
be any positive integer. Values known to me are 47 and 56.
.sp
Default value: 47
.br
Minimum: 0
.br
Maximum: none
.br
.sp
Example: option top 56
.TP
.B waitbank <value>
The number of usecs to wait for a bank change. You should not touch this
value actually. May be any positive integer
.sp
Default value: 700
.br
Minimum: 0
.br
Maximum: none
.sp
Example: option waitbank 700
.PP
A sample configuration file is shown below:
.PP
.EX
#
# LifeTec/Medion 9350 on port 0x378
#
scanner "LifeTec 9350" 0x378 cis1200
# Some calibration options (examples!).
option bw 127
option top_skip \-0.8
#
# A Mustek 600CP on port 0x3BC
#
scanner "Mustek 600CP" 0x3BC cis600
# Some calibration options (examples!).
option bw 120
option top_skip 1.2
#
# A Mustek 1200CP+ on port 0x278
#
scanner "Mustek 1200CP plus" 0x278 cis1200+
# Some calibration options (examples!).
option bw 130
option top_skip 0.2
#
# A Mustek 600 III EPP on port parport0
#
scanner "Mustek 600 III EPP" parport0 ccd300
# Some calibration options (examples!).
option bw 130
option top 56
.EE
.SH GLOBAL OPTIONS
.PP
You can control the overall behaviour of the
.B sane-\mustek_pp
backend by global
options which precede any scanner definition in the
.I mustek_pp.conf
file.
.sp
Currently, there is only one global option:
.SS Global options
.TP
.B no_epp
Disable parallel port mode EPP: works around a known bug in the Linux parport
code. Enable this option, if the backend hangs when trying to access the
parallel port in EPP mode.
.sp
Default value: use EPP
.sp
Example: option no_epp
.SH FILES
.TP
.I @CONFIGDIR@/mustek_pp.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I @LIBDIR@/libsane\-mustek_pp.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane\-mustek_pp.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file. On *NIX systems, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in
.IR @CONFIGDIR@ .
If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories. For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories
.IR "tmp/config" ,
.IR "." ,
and
.I "@CONFIGDIR@"
being searched (in this order).
.TP
.B SANE_DEBUG_MUSTEK_PP
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. E.g.,
a value of 128 requests all debug output to be printed. Smaller
levels reduce verbosity.
.EX
level debug output
--------------------------------------
0 nothing
1 errors
2 warnings & minor errors
3 additional information
4 debug information
5 code flow (not supported yet)
6 special debug information
.EE
.TP
.B SANE_DEBUG_SANEI_PA4S2
This variable sets the debug level for the SANE interface for the Mustek
chipset A4S2. Note that enabling this will spam your terminal with some
million lines of debug output.
.EX
level debug output
----------------------------
0 nothing
1 errors
2 warnings
3 things nice to know
4 code flow
5 detailed code flow
6 everything
.EE
.SH "SEE ALSO"
.BR sane (7),
.BR sane\-mustek (5),
.BR sane\-net (5),
.BR saned (8),
.BR sane\-find\-scanner (1),
.BR scanimage (1)
.TP
For latest bug fixes and information see
.I http://www.penguin\-breeder.org/sane/mustek_pp/
.TP
For additional information on the CIS driver, see
.I http://home.scarlet.be/eddy_de_greef/
.SH AUTHORS
.nf
Jochen Eisinger
.RI < "jochen at penguin\-breeder dot org" >
Eddy De Greef
.RI < "eddy_de_greef at scarlet dot be" >
.fi
.SH BUGS
Too many... please send bug reports to
.I sane\-devel@alioth-lists.debian.net
(note that you have to subscribe first to the list before you can send
emails... see
.IR http://www.sane\-project.org/mailing\-lists.html ).
.SH BUG REPORTS
If something doesn't work, please contact us (Jochen for the CCD scanners,
Eddy for the CIS scanners). But we need some information about
your scanner to be able to help you...
.TP
.I SANE version
Run
.I scanimage \-V
to determine this.
.TP
.I the backend version and your scanner hardware
Run
.I SANE_DEBUG_MUSTEK_PP=128 scanimage \-L
as root. If you don't get any output from the
.BR sane\-mustek_pp
backend, make sure a line "mustek_pp" is included into your
.IR @CONFIGDIR@/dll.conf .
If your scanner isn't detected, make sure you've defined the right port address
in your
.IR mustek_pp.conf .
.TP
.I the name of your scanner/vendor also a worthy information. Please also include the
optical resolution and lamp type of your scanner, both can be found in the manual of
your scanner.
.TP
.I any further comments
if you have comments about the documentation (what could be done better), or you
think I should know something, please include it.
|