diff options
Diffstat (limited to 'data/logs/Hewlett-Packard_PSC_1500_series.log')
-rw-r--r-- | data/logs/Hewlett-Packard_PSC_1500_series.log | 75 |
1 files changed, 75 insertions, 0 deletions
diff --git a/data/logs/Hewlett-Packard_PSC_1500_series.log b/data/logs/Hewlett-Packard_PSC_1500_series.log new file mode 100644 index 0000000..e87292d --- /dev/null +++ b/data/logs/Hewlett-Packard_PSC_1500_series.log @@ -0,0 +1,75 @@ +[+0,00s] DEBUG: simple-scan.vala:637: Starting Simple Scan 3.28.0, PID=11070 +[+0,03s] CRITICAL: g_action_print_detailed_name: assertion 'g_action_name_is_valid (action_name)' failed +[+0,03s] CRITICAL: gtk_application_set_accels_for_action: assertion 'detailed_action_name != NULL' failed +[+0,05s] DEBUG: app-window.vala:1671: Restoring window to 600x400 pixels +[+0,05s] DEBUG: autosave-manager.vala:64: Loading autosave information +[+0,05s] DEBUG: autosave-manager.vala:259: Waiting to autosave... +[+0,10s] DEBUG: scanner.vala:1454: sane_init () -> SANE_STATUS_GOOD +[+0,10s] DEBUG: scanner.vala:1460: SANE version 1.0.27 +[+0,10s] DEBUG: scanner.vala:1521: Requesting redetection of scan devices +[+0,10s] DEBUG: scanner.vala:806: Processing request +[+0,15s] DEBUG: autosave-manager.vala:281: Autosaving book information +[+2,30s] DEBUG: simple-scan.vala:454: Requesting scan at 150 dpi from device '(null)' +[+2,30s] DEBUG: scanner.vala:1569: Scanner.scan ("(null)", dpi=150, scan_mode=ScanMode.GRAY, depth=2, type=ScanType.SINGLE, paper_width=2100, paper_height=2970, brightness=0, contrast=0, delay=10000ms) +[+6,46s] DEBUG: scanner.vala:341: sane_get_devices () -> SANE_STATUS_GOOD +[+6,46s] DEBUG: scanner.vala:353: Device: name="hpaio:/usb/PSC_1500_series?serial=MY63DCC18J04GG" vendor="Hewlett-Packard" model="PSC_1500_series" type="all-in-one" +[+6,46s] DEBUG: scanner.vala:806: Processing request +[+8,53s] DEBUG: scanner.vala:867: sane_open ("hpaio:/usb/PSC_1500_series?serial=MY63DCC18J04GG") -> SANE_STATUS_GOOD +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (0) +[+8,53s] DEBUG: scanner.vala:738: Option 0: title='Number of options' type=int size=4 cap=soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Read-only option that specifies how many options a specific devices supports. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (1) +[+8,53s] DEBUG: scanner.vala:738: Option 1: name='(null)' title='Scan mode' type=group size=0 +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (2) +[+8,53s] DEBUG: scanner.vala:738: Option 2: name='mode' title='Scan mode' type=string size=20 values=["Lineart", "Gray", "Color"] cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Selects the scan mode (e.g., lineart, monochrome, or color). +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (3) +[+8,53s] DEBUG: scanner.vala:738: Option 3: name='resolution' title='Scan resolution' type=int size=4 unit=dpi values=[75, 100, 150, 200, 300, 600, 1200] cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Sets the resolution of the scanned image. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (4) +[+8,53s] DEBUG: scanner.vala:738: Option 4: name='(null)' title='Advanced' type=group size=0 cap=advanced +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (5) +[+8,53s] DEBUG: scanner.vala:738: Option 5: name='contrast' title='Contrast' type=int size=4 min=-127, max=127, quant=0 cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Controls the contrast of the acquired image. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (6) +[+8,53s] DEBUG: scanner.vala:738: Option 6: name='brightness' title='Brightness' type=int size=4 min=-127, max=127, quant=0 cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Controls the brightness of the acquired image. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (7) +[+8,53s] DEBUG: scanner.vala:738: Option 7: name='compression' title='Compression' type=string size=20 values=["None", "JPEG"] cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Selects the scanner compression method for faster scans, possibly at the expense of image quality. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (8) +[+8,53s] DEBUG: scanner.vala:738: Option 8: name='jpeg-quality' title='JPEG compression factor' type=int size=4 min=0, max=100, quant=0 cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Sets the scanner JPEG compression factor. Larger numbers mean better compression, and smaller numbers mean better image quality. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (9) +[+8,53s] DEBUG: scanner.vala:738: Option 9: name='batch-scan' title='Batch scan' type=bool size=4 cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Enables continuous scanning with automatic document feeder (ADF). +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (10) +[+8,53s] DEBUG: scanner.vala:738: Option 10: name='source' title='Scan source' type=string size=20 values=["Flatbed"] cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Selects the scan source (such as a document-feeder). +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (11) +[+8,53s] DEBUG: scanner.vala:738: Option 11: name='duplex' title='Duplex' type=bool size=4 cap=soft-select,soft-detect,inactive,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Enables scanning on both sides of the page. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (12) +[+8,53s] DEBUG: scanner.vala:738: Option 12: name='(null)' title='Geometry' type=group size=0 cap=advanced +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (13) +[+8,53s] DEBUG: scanner.vala:738: Option 13: name='length-measurement' title='Length measurement' type=string size=20 values=["Unknown", "Approximate", "Padded"] cap=soft-select,soft-detect,advanced +[+8,53s] DEBUG: scanner.vala:741: Description: Selects how the scanned image length is measured and reported, which is impossible to know in advance for scrollfed scans. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (14) +[+8,53s] DEBUG: scanner.vala:738: Option 14: name='tl-x' title='Top-left x' type=fixed size=4 unit=mm min=0,000000, max=215,899994, quant=0 cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Top-left x position of scan area. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (15) +[+8,53s] DEBUG: scanner.vala:738: Option 15: name='tl-y' title='Top-left y' type=fixed size=4 unit=mm min=0,000000, max=296,925995, quant=0 cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Top-left y position of scan area. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (16) +[+8,53s] DEBUG: scanner.vala:738: Option 16: name='br-x' title='Bottom-right x' type=fixed size=4 unit=mm min=0,000000, max=215,899994, quant=0 cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Bottom-right x position of scan area. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (17) +[+8,53s] DEBUG: scanner.vala:738: Option 17: name='br-y' title='Bottom-right y' type=fixed size=4 unit=mm min=0,000000, max=296,925995, quant=0 cap=soft-select,soft-detect +[+8,53s] DEBUG: scanner.vala:741: Description: Bottom-right y position of scan area. +[+8,53s] DEBUG: scanner.vala:888: sane_get_option_descriptor (18) +[+8,53s] DEBUG: scanner.vala:549: sane_control_option (10, SANE_ACTION_SET_VALUE, "Flatbed") -> (SANE_STATUS_GOOD, "Flatbed") +[+8,53s] DEBUG: scanner.vala:549: sane_control_option (2, SANE_ACTION_SET_VALUE, "Gray") -> (SANE_STATUS_GOOD, "Gray") +[+8,53s] DEBUG: scanner.vala:428: sane_control_option (9, SANE_ACTION_SET_VALUE, SANE_FALSE) -> (SANE_STATUS_GOOD, SANE_FALSE) +[+8,53s] DEBUG: scanner.vala:549: sane_control_option (7, SANE_ACTION_SET_VALUE, "None") -> (SANE_STATUS_GOOD, "None") +[+8,53s] DEBUG: scanner.vala:465: sane_control_option (3, SANE_ACTION_SET_VALUE, 150) -> (SANE_STATUS_GOOD, 150) +[+8,53s] DEBUG: scanner.vala:505: sane_control_option (16, SANE_ACTION_SET_VALUE, |