diff options
Diffstat (limited to 'help/C')
| -rw-r--r-- | help/C/adf.page | 7 | ||||
| -rw-r--r-- | help/C/brightness-contrast.page | 6 | ||||
| -rw-r--r-- | help/C/dpi.page | 9 | ||||
| -rw-r--r-- | help/C/figures/preferences.png | bin | 18646 -> 46262 bytes | |||
| -rw-r--r-- | help/C/figures/scan_toolbar.png | bin | 27643 -> 17368 bytes | |||
| -rw-r--r-- | help/C/figures/scanner_selection.png | bin | 0 -> 8453 bytes | |||
| -rw-r--r-- | help/C/quality.page | 17 | ||||
| -rw-r--r-- | help/C/scanner.page | 2 | ||||
| -rw-r--r-- | help/C/scanning.page | 2 | 
9 files changed, 28 insertions, 15 deletions
| diff --git a/help/C/adf.page b/help/C/adf.page index 7c6f81b..83d8274 100644 --- a/help/C/adf.page +++ b/help/C/adf.page @@ -32,7 +32,7 @@        <steps>  	<title>Use the Toolbar</title>  	<item> -          <p>Click the arrow to the right of the <gui style="button">Scan</gui> button.</p> +          <p>Click the cog to the right of the <gui style="button">Scan</gui> button.</p>  	</item>  	<item>  	  <p>Select <gui style="button">All Pages From Feeder</gui>.</p> @@ -50,10 +50,7 @@          <gui style="menuitem">Preferences</gui>.</p>        </item>        <item> -        <p>Select <gui style="tab">Scanning</gui>.</p> -      </item> -      <item> -        <p>Change the <gui>Scan Sides</gui> value.</p> +        <p>In <gui style="group">Scanning</gui> section change the <gui>Scan Sides</gui> value.</p>        </item>        <item>          <p>Close the dialog.</p> diff --git a/help/C/brightness-contrast.page b/help/C/brightness-contrast.page index 79007ac..baf5c69 100644 --- a/help/C/brightness-contrast.page +++ b/help/C/brightness-contrast.page @@ -29,13 +29,11 @@        <gui style="menuitem">Preferences</gui>.</p>      </item>      <item> -      <p>Select <gui style="tab">Quality</gui>.</p> -    </item> -    <item> -      <p>Drag the <gui>Brightness</gui> and/or <gui>Contrast</gui> sliders.</p> +      <p>In <gui style="group">Quality</gui> section drag the <gui>Brightness</gui> and/or <gui>Contrast</gui> sliders.</p>      </item>      <item>        <p>Close the dialog.</p> +      <media type="image" src="figures/preferences.png" />      </item>    </steps> diff --git a/help/C/dpi.page b/help/C/dpi.page index 92ecea7..0bdeef0 100644 --- a/help/C/dpi.page +++ b/help/C/dpi.page @@ -29,10 +29,7 @@          <gui style="menuitem">Preferences</gui>.</p>        </item>        <item> -        <p>Select <gui style="tab">Quality</gui>.</p> -      </item> -      <item> -        <p>Change the <gui>Text Resolution</gui> or <gui>Image Resolution</gui> value.</p> +        <p>In <gui style="group">Quality</gui> section change the <gui>Text Resolution</gui> or <gui>Image Resolution</gui> value.</p>        </item>        <item>          <p>Close the dialog.</p> @@ -56,6 +53,10 @@  		<td><p>150 dpi</p></td>  	</tr>  	<tr> +		<td><p>200 dpi</p></td> +		<td><p>200 dpi</p></td> +	</tr> +	<tr>  		<td><p>300 dpi</p></td>  		<td><p>300 dpi (default)</p></td>  	</tr> diff --git a/help/C/figures/preferences.png b/help/C/figures/preferences.pngBinary files differ index 1906738..55cf233 100644 --- a/help/C/figures/preferences.png +++ b/help/C/figures/preferences.png diff --git a/help/C/figures/scan_toolbar.png b/help/C/figures/scan_toolbar.pngBinary files differ index a708e3e..05bd815 100644 --- a/help/C/figures/scan_toolbar.png +++ b/help/C/figures/scan_toolbar.png diff --git a/help/C/figures/scanner_selection.png b/help/C/figures/scanner_selection.pngBinary files differ new file mode 100644 index 0000000..778a0aa --- /dev/null +++ b/help/C/figures/scanner_selection.png diff --git a/help/C/quality.page b/help/C/quality.page index 8132e1e..617ab19 100644 --- a/help/C/quality.page +++ b/help/C/quality.page @@ -18,9 +18,24 @@  	<title>Setting the Image Quality</title>      <p> -    You can adjust the image quality that is used when the scan is converted to a file by changing this setting in the save dialog. +    You can adjust the image quality that is used when the scan is converted to a file by changing this setting in the preferences dialog.      Using a low quality will result in a small file size but may show some blurring or blockiness in the image.      A high quality will keep all the scanned information but require a larger file size.      See the <link href="https://en.wikipedia.org/wiki/Lossy_compression">Lossy compression Wikipedia page</link> for more information.      </p>     + +    <steps> +        <item> +          <p>Press the menu button in the top-right corner of the window and select +          <gui style="menuitem">Preferences</gui>.</p> +        </item> +        <item> +          <p>In <gui style="group">Quality</gui> section drag the <gui>Compression</gui> slider.</p> +        </item> +        <item> +          <p>Close the dialog.</p> +          <media type="image" src="figures/preferences.png" /> +        </item> +    </steps> +  </page> diff --git a/help/C/scanner.page b/help/C/scanner.page index 3d57731..79144f2 100644 --- a/help/C/scanner.page +++ b/help/C/scanner.page @@ -28,4 +28,6 @@      scanner you will need to restart <app>Document Scanner</app> for the scanner      to be detected.      </p> +     +    <media type="image" src="figures/scanner_selection.png" />  </page> diff --git a/help/C/scanning.page b/help/C/scanning.page index 4502c0d..884a521 100644 --- a/help/C/scanning.page +++ b/help/C/scanning.page @@ -26,7 +26,7 @@      <steps>        <item><p>Connect the scanner to your computer and power it on.</p></item>        <item><p>Open <app>Document Scanner</app>.</p></item> -      <item><p>Click the arrow to the right of the <gui style="button">Scan</gui> button.</p></item> +      <item><p>Click the cog to the right of the <gui style="button">Scan</gui> button.</p></item>        <item><p>Select the type of document you are scanning: <gui style="button">Text</gui> or <gui style="button">Image</gui>.</p>  	     <media type="image" src="figures/scan_toolbar.png"/></item>        <item><p>Click the "Scan" button on the toolbar (or press <keyseq><key>Ctrl</key><key>1</key></keyseq>).</p></item> | 
